The Agilent/Keysight E1441A is a C-size VXI arbitrary waveform generator employing direct digital synthesis to produce standard and custom waveforms for electronic testing, simulation, and communication system development. This message-based module delivers isolated output design that minimizes ground loops and common-mode noise, enhancing signal integrity across complex measurement scenarios. The E1441A provides substantial waveform generation capability at lower cost than comparable standalone function generators. Note: This product is obsolete due to non-compliance with EU RoHS directive 2011/65/EU; Keysight continues service and support through its published end-of-life date.
– Technical Specifications
Waveform Generation
• Arbitrary waveform resolution: 12-bit
• Maximum sample rate: 40 MSa/s
• Memory capacity: Up to 16,000 points per waveform; four 16k-deep arbitrary waveforms
• Waveform point range: 8 to 8,192 points, extendable to 16,000 points
Frequency Performance
• Sine/square wave output: 100 µHz to 15 MHz
• Triangle/ramp wave output: 100 µHz to 100 kHz
• Gaussian noise bandwidth: 10 MHz
• Sine wave flatness <100 kHz: ±1% (0.1 dB)
• Sine wave flatness 100 kHz–1 MHz: ±1.5% (0.15 dB)
• Sine wave flatness 1–15 MHz: ±2% (0.2 dB)
Output Specifications
• Amplitude into 50 Ω: 50 mVp-p to 10 Vp-p
• Amplitude into open-circuit load: 100 mVpp to 20 Vpp
• Output impedance: 50 Ω fixed
• Amplitude accuracy at 1 kHz: ±1% of specified output
• Offset range into 50 Ω: ±5 Vpk AC + DC
• Isolation voltage to earth ground: 42 Vpk maximum
• Output protection: Short-circuit protection; ±15 Vpk overdrive (<1 minute)
• Setting resolution: 3 digits (amplitude and offset)
• Output units: Vpp, Vrms, dBm
Built-in Waveforms
• Sine, square, triangle, ramp, Gaussian noise, sinc (sin(x)/x), exponential rise/fall, cardiac, DC voltage
Modulation & Sweep
• Internal modulation: AM, FM, FSK, burst
• Sweep types: Linear, logarithmic
– Key Features
• Message-based VXI architecture for remote command-driven operation
• Isolated output eliminates ground-loop interference
• Non-volatile waveform storage
• Direct digital synthesis for precise frequency control
• Four independent 16k-point arbitrary waveform slots
• Optional high-stability timebase (Option 001)
– Typical Applications
• RF and baseband signal simulation
• Component and subsystem characterization
• Communication system development and validation
• General-purpose function generation in VXI test racks
– Compatibility & Integration
Designed as a single C-size VXI slot module, the E1441A integrates into standard VXIbus mainframes supporting message-based instrument control.



























Reviews
There are no reviews yet.