The Agilent/Keysight N1094B DCA-M is a compact, high-performance sampling oscilloscope engineered for precise signal characterization and analysis in high-speed digital and optical communication systems. It features four electrical channels, enabling simultaneous measurement of multiple signals, and is designed for applications requiring accurate waveform analysis, such as eye diagram analysis, jitter measurement, and compliance testing in R&D and manufacturing environments.
### Technical Specifications
* **Bandwidth:** User selectable options include 20/30 GHz or 20/33/40/50 GHz.
* **Electrical Channel Count:** 4 channels.
* **Input Connectors:** 2.4 mm (m) bulkhead.
* **Noise Floors:**
* 310 µV (at 20 GHz).
* 600 µV (at 50 GHz).
* **Jitter:** Less than 170 fs for accurate high data rate analysis.
* **Sample Rate:** High throughput of 250 kHz.
* **Transition Time (10% to 90% calculated from TR = 0.35/BW):**
* 20 GHz BW: 17.5 ps (Calculated).
* 33 GHz BW: [No specific value found].
* **Clock Input Range:** 500 MHz to 28.5 GHz.
* **Maximum Non-Destructive Clock Input Voltage:** 1.4 Vpp.
### Electrical Characteristics
* **Nominal Voltage and/or Range:** 100/120 Vac, 50/60/400 Hz; 220/240 Vac, 50/60 Hz.
* **Power Consumption:** 290 Watts Maximum.
* **Mains Supply Voltage Fluctuations:** The unit can operate with fluctuations up to ±10% of the nominal voltage.
### Interfaces and Control
* **Control:** The N1094B can be controlled via:
* A PC directly connected with a USB cable.
* An 86100D or N1000A mainframe connected via USB, which can then be controlled via GPIB or LAN.
* A primary test system PC connected to a modern PC via LAN, with the FlexDCA interface residing on the second PC, which is then connected to the N109X via USB.
* **Software:** Control is managed by a user-provided PC running N1010A FlexDCA software over a USB 2.0 or 3.0 connection.
* **Communication API:** SCPI over LAN (VXI-11 or HiSlip).
### Physical Characteristics
* **Dimensions:** 16 × 14 × 10 in.
* **Weight:** 25 lbs.
* **Form Factor:** Compact design.
### Compatibility and Software
* **Operating System Requirements for Controlling PC (FlexDCA):**
* **Single Channel Setup:** Intel I3 processor or better, 4 GB memory, Windows 7 (32 or 64 bit).
* **Parallel Test Setup (multiple instruments or channels):** Intel I5 or better, 8 GB memory, Windows 7 (64 bit).
* **Software:** N1010A FlexDCA software is required on the controlling PC and is available as a free download.
* **Legacy Compatibility:** Remote programs developed using the 86100 or N1000 FlexDCA interface can be leveraged to control an automated N109X system.
### Measurement Capabilities
* Eye-mask mode tests and measurement of eye diagram parameters, including extinction ratio.
* Basic oscilloscope mode measurements of pulses (limited to patterns less than 2 ns in duration).
* Optical transmitter compliance tests at standard data rates from 1.25 to 11.3 Gb/s.
* Pattern lock trigger functionality (requires option PLK).
Why Choose Aumictech for the Agilent/Keysight N1094B DCA-M Sampling Oscilloscope?
At Aumictech, we specialize in supplying high-performance test and measurement equipment. Whether you need to characterize high-speed digital signals, perform precise jitter analysis, or ensure compliance with industry standards, our team ensures the Agilent/Keysight N1094B DCA-M delivers maximum performance for your demanding applications.