The Elgar 5.0-13A is an AC power source engineered for robust performance in diverse electronic testing and power application scenarios. It is recognized for its stable and dependable power output, making it suitable for demanding laboratory and industrial environments where precision and reliability are paramount. This unit offers advanced waveform creation capabilities for automated test equipment (ATE) and power line disturbance simulations.
### Technical Specifications
**General**
* **Manufacturer:** Elgar
* **Product Line:** SmartWave™ (SW) Series
* **Power Output:** Models within the SW Series are expandable from 1.75 kVA to 22.2 kVA. Specific configurations for the SW 5250A indicate total power capabilities ranging from 5250/5550 VA for single or three-phase output, up to 22,200 VA.
* **Configuration:** Available in single-phase, two-phase, or three-phase configurations.
* **Operating Temperature:** Delivers full rated power up to 45°C.
**Electrical Specifications**
* **Output Voltage Ranges:**
* Range 1: 0 to 156 Vrms Line-to-Neutral (L-N)
* Range 2: 0 to 312 Vrms L-N
* Some models within related series offer voltage ranges up to 600V.
* **Output Current Per Phase:**
* Per 1750/1850 VA module: 13/16A at 135V (156V range); 6.5/13A at 270V (312V range).
* Higher currents may be achieved in systems with higher kVA ratings.
* **Output Frequency Range:**
* DC or 2 Hz to 6 kHz.
* Specifications typically apply from DC, 40 Hz to 5 kHz.
* For output frequencies greater than 1 kHz, the maximum slew rate allowed is 1 kHz per second.
* **Power Factor (Output Load):** 0 (lagging) to unity.
* **Crest Factor:** 4.0 (peak output current to RMS output current).
* **Total Harmonic Distortion (THD):**
* 0.25% maximum (full linear load or no load), 40 to 100 Hz.
* 0.5% maximum to 500 Hz.
* 1% maximum to 1 kHz, plus 1% per kHz to 5 kHz.
* **AC Noise Level:** Greater than 60 dB RMS below full output voltage.
* **Amplitude Stability (with Remote Sense):** ±0.1% of full scale over 24 hours at constant line, load, and temperature.
* **Load Regulation:** ±0.025% of full scale voltage for a full resistive load to no load; above 1 kHz, add ±0.015% per kHz.
* **Line Regulation:** ±0.025% of full scale for a ±10% input line change (DC, or 40 Hz to 5 kHz).
* **Voltage Accuracy:** ±0.1% of range (valid for 5 to 156 Vrms and 10 to 312 Vrms at 25°C, sense leads connected). Above 1 kHz, add 0.2% per kHz. Add ±0.1% of full scale for “AC PLUS DC” mode. Temperature coefficient is less than 50 ppm/°C.
* **Voltage Resolution:** 0.05% of full scale.
* **Frequency Resolution:** 0.01 Hz (40 to 99.99 Hz), 0.05 Hz (100 to 999.9 Hz), 0.5 Hz (1000 to 5000 Hz).
* **Frequency Accuracy:** ±0.01% at 25°C ±0.001% per °C.
* **Phase Accuracy (Phase-to-Phase Balanced Linear Resistive Load):** ±1° (40 Hz to 1 kHz), plus ±1° per kHz above 1 kHz.
* **Phase Angle Resolution:** 0.1°.
* **Remote Output Voltage Sense:** 5 Vrms total lead drop, maximum.
* **Output Impedance:** Specific values vary by model and configuration, refer to detailed datasheets. For SW 5250A in 312V range, it meets requirements of IEC-1000-3-2, Annex A, Supply Source.
**Input Specifications**
* **Voltage Ranges:** Factory configured options include:
* 187 to 264 Vrms, 3-phase L-L (3-wire)
* 342 to 457 Vrms, 3-phase L-L (4-wire)
* Other documented input voltages for related models include 115 or 230 VAC and 87-264 VRMS (L-L), 3-wire for SW5250A.
* Single-phase 115 or 230 VAC is required for PDU in 10.5-21 kVA systems.
* 400 Hz input is allowed with PFC option.
* **Input Frequency Range:** 47 to 63 Hz. Some configurations support up to 440 Hz with PFC input.
* **Power Factor (Input):**
* 0.6 (standard).
* .35 for Intl. Rectifier.
* 0.99 with PFC option. (With PFC option, inputs may be paralleled and wired for single-phase input; consult factory).
* **Efficiency:** 70% minimum at full load.
* **Ride Through:** 3 ms minimum; 10 ms minimum with PFC option.
**Waveform Generation and Control**
* **Arbitrary Waveform Generators:** Three separate arbitrary waveform generators enable creation of independent, complex waveforms on all three phases simultaneously.
* **Waveform Capabilities:** Can create fractional or multi-cycle dropouts, spikes, surges, sags, and distorted waveforms from the front panel.
* **Built-in Waveshapes:** Includes a library of 50 built-in waveshapes, with the ability to create and store an additional 50 user-defined waveshapes.
* **Sequencing:** Sequences can be constructed with segments defined by time or number of cycles.
* **Control Software:** SMARTWAVE CONTROL SUITE (SWCS) provides PC control for setting parameters, creating/editing waveforms, logging measurements, and managing sequences.
**Interfaces**
* **Front Panel Control:** Features for setting voltage, frequency, current limit, and waveform type.
* **Remote Control:** GPIB command control is accessible.
* **External Modulation/Drive:**
* External Amplitude Modulation: 0 to 5 Vrms provides 0 to ≥20% output amplitude modulation.
* External Drive: 0 to 5 Vrms (DC to 5 kHz) or ±5 VDC input for zero to full voltage output.
* External Gain Control: 0 to ±7.07 VDC provides zero to full output.
* **External Input Impedance:** ≥30 kΩ.
* **Remote Output Voltage Sense:** Supported.
* **Output Relay:** Optional internal output relay connectable under GPIB control or front panel keypad.
**Physical**
* **Form Factor:** Often designed for rack mounting, with specific models having heights such as 8-3/4 inches (222 mm) for the SW 5250A. Standard rack width of 19 inches (483 mm) and depth of 23.5 inches (597 mm) are noted for some SW series units.
* **Cooling:** Air is drawn through a front panel grill and exhausted at the rear panel grill.
* **Weight:** Specific models like the SW5250A are documented with a weight of 127 Lbs.
**Compatibility and Standards**
* **Test Standards:** Designed to meet requirements for various testing standards, including MIL-STD-704, DO-160, and ABD100. Related series also support compliance testing for EMC and avionics standards.
* **Harmonics:** Compliant with IEC-1000-3-2, Annex A, Supply Source requirements.
### Why Choose Aumictech for ELGAR 5.0-13A?
At Aumictech, we specialize in supplying high-end programmable AC power sources and associated test equipment. Whether you need precise power simulation for avionics testing, stable power for demanding electronic loads, or advanced waveform generation for product validation, our team ensures the ELGAR 5.0-13A delivers maximum performance and reliability for your critical applications.





















Reviews