The Elgar 501SL is a single-phase AC power source designed for precise AC power generation, offering variable voltage and frequency for a wide range of testing applications. This unit is suitable for simulating global power conditions and verifying the performance of electronic equipment under various operational parameters. The SL series, including the 501SL, is engineered for reliability and control, making it a valuable asset in laboratory, industrial, and ATE (Automatic Test Equipment) environments. Its solid-state linear amplifier design ensures a clean, low-distortion sine wave output.
### Technical Specifications
* **Model:** Elgar 501SL
* **Product Type:** Single-Phase AC Power Source
* **Output Power:** 500 VA (Volt-Amperes)
* Continuous duty at 150% of rated capacity into linear resistive loads
* **Output Voltage Range:**
* Typically 0-65 VAC, 0-130 VAC, or 0-260 VAC
* Specific output voltage options include 0-32V
* Nominal output voltages of 28, 115, and 230 VAC are available
* Adjustable over a specified range (e.g., 55-65 VAC, 110-130 VAC, or 220-260 VAC for full rated VA)
* **Output Frequency Range:**
* 45 Hz to 5000 Hz
* Expandable to 10 kHz
* Can operate over frequency ranges such as 45 Hz to 480 Hz or 47 Hz to 63 Hz
* Can be driven over its full voltage and frequency ranges by plug-in oscillators
* **Input Voltage:**
* 115 VAC at 50 or 60 Hz
* 115 VAC, 208 VAC, or 230 VAC, +10% (208 VAC not available on all models)
* 115VAC 1 Phase 47-63 Hz
* **Harmonic Distortion:** Typically better than 0.4%, normally below 0.3% midband, 0.6% over full frequency range
* **Load Power Factor:** Unity to ±0.7 PF at rated VA
* **Line Regulation:** ±0.25% at rated load for a +10% input change at full scale output voltage
* **Load Regulation:** Better than ±0.25% for fixed frequency output, adjustable to ±0.1% for specific load conditions
* **AC Noise Level:** 70 dB below full output voltage with input grounded
### Electrical Characteristics
* **Overload Protection:** Included
* **Over-temperature Protection:** Included
* **Output Impedance:** Low effective output impedance
* **Capacitors:** May retain an electrical charge even when power is off
### Interfaces & Programmability
* **Programmability:** Manual or IEEE-488 (GPIB) programmable using Elgar’s Plug-In Programmers (PIP)
* Full GPIB control of voltage, frequency, phase angle, voltage dropouts, and test readback of output parameters when used with a PIP
* **Oscillator Modules:**
* Requires plug-in oscillator modules for frequency control
* Various oscillator modules are available, including fixed frequency and variable frequency types (e.g., Elgar 401SD, 401V, 461-.01, 441-.1, 9012A)
* Oscillator modules are sold separately
* **Range Change Option:** Optional internal range change relays can switch between output voltage ranges (e.g., 130 VAC and 260 VAC) via GPIB or front panel control when used with a compatible PIP or oscillator
* **Output Relay Option:** An optional internal output relay can connect the load to the output under GPIB control
* **Remote Sense:** Available with a PIP and selected oscillators
* **Current Limit Feedback:** Optional internal current transformer can provide current limit feedback to the PIP oscillator
* **Built-In-Test-Equipment (BITE):** Optional with specific PIPs (e.g., PIP 704, PIP 9012A, PIP 9023), allowing measurement and reporting of RMS voltage, RMS current, frequency, phase angle, and RMS power in watts
* **J1 Interface Connector:** 15-pin connector for configuration flexibility
* **Sync Input/Output:** Rear panel BNC connectors for oscillator sync input/output
### Physical Characteristics
* **Dimensions:**
* 5.25 inches (133 mm) high x 19 inches (483 mm) wide x 21 inches (533 mm) deep
* **Rack Mounting:** Standard 19-inch RETMA rack mounting
* **Weight:**
* Net Weight: 75 pounds (34 kg)
* Shipping Weight: 83 pounds (38 kg)
* **Cooling:** Single fan with side air intake and rear air exhaust
* **Front Panel Meter:** 0 to 300 VAC voltmeter with ±3% accuracy over the 45 Hz to 1 kHz frequency range
* **Front Panel Controls:** Input power switch/circuit breaker, 10-turn output voltage control potentiometer
### Compatibility & Applications
* **Series and Paralleling Capabilities:** The units can be used in series or parallel configurations
* **Applications:**
* General purpose test applications
* ATE systems
* Avionics testing
* Simulating global power conditions
* Testing electronic equipment
* Testing linear loads over their full voltage and frequency ranges
### Safety Considerations
* **Hazardous Voltages:** Hazardous voltages in excess of 280 VAC may be present at input and output terminals. Internal DC supply voltages of ±50 VDC are present, capable of high short circuit currents.
* **Qualified Personnel:** Installation and servicing must be performed by qualified personnel aware of attendant hazards.
* **Grounding:** Ensure proper power line ground connection to the input terminal. All power ground lines to application and maintenance equipment must be properly grounded.
* **Electrical Shock Risk:** Avoid touching any electrical circuits, even when power is off, as capacitors may retain a charge. Use safety glasses during open-cover checks.
* **Output Labeling:** The user must ensure output power and sense lines are properly labeled regarding safety hazards to eliminate inadvertent contact with hazardous voltages.
Why Choose Aumictech for the ELGAR 501SL?
At Aumictech, we specialize in supplying high-end AC power sources and test equipment. Whether you need precise voltage and frequency simulation, robust power delivery for equipment testing, or reliable performance for ATE systems, our team ensures the ELGAR 501SL delivers maximum performance and value for your application.