Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST Calibration Available on demand.

Service Support

Service plans available for the products’ durability

FAST REPAIRS

Overnight repairs available for selected products

Software Updates 

Staying up-to-date with lastest software updates.

Lifetime Support by Aumictech
Free OEM-grade Calibration
Fastest turnaround times

Repair and Service Evaluation – HP/Agilent E7401A, E7402A, E7403A, E7404A, E7405A

SKU: E7401A, E7402A, E7403A, E7404A, E7405ACategories: Service and Repairs
30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • 100% Verified & Tested Equipment
  • Rental Units Available

Repair evaluation service for HP/Agilent E7401A, E7402A, E7403A, E7404A, and E7405A spectrum analyzers. This service provides a comprehensive assessment of the instrument’s condition to determine the necessary repairs.

Request Repair
Product Starting From:

$100.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote E7401A, E7402A, E7403A, E7404A, E7405A
Equipment info

The HP/Agilent E7400A series spectrum analyzers (E7401A, E7402A, E7403A, E7404A, E7405A) are full-featured instruments engineered for EMI pre-compliance testing and in-house product evaluation during development. These analyzers enable early identification and resolution of potential emissions issues before formal compliance testing. Operating as standalone spectrum analyzers or integrated with broadband antennas and Line Impedance Stabilization Networks (LISNs), they assess both radiated and conducted emissions across device power and data lines. Close-field probe accessories such as the 11940A and 11941A support focused troubleshooting and source isolation when emissions problems are identified.

– Technical Specifications

Frequency Performance
• Frequency reference accuracy: ±(frequency indication × frequency reference error + span accuracy + 15% of RBW + 10 Hz) + 1 Hz × N (where N is LO harmonic mixing mode)
• Frequency reference error: Aging rate ±1 × 10⁻⁷/year; temperature stability ±1 × 10⁻⁸
• Marker frequency counter accuracy: ±(marker frequency × frequency reference error + counter resolution)
• Counter resolution: Selectable 1 Hz to 100 kHz
• Frequency span range: 0 Hz (zero span) to full analyzer range
• Span accuracy: Linear sweep ±0.5% of span; log sweep ±2% of span (characteristic)

Amplitude Performance
• Displayed average noise level (DANL): Typically ≤ −150 dBm
• Third order intercept (TOI): Typically +12.5 dBm
• Second harmonic distortion (SHI): Typically +45 dBm
• Resolution bandwidth (RBW): 1 Hz to 3 MHz (−3 dB) in 1-3-10 sequence; extendable to 5 MHz on E740x A models
• Video bandwidth (VBW): 30 Hz to 3 MHz in 1-3-10 sequence; range 1 Hz to 3 MHz with 1 Hz to 300 Hz available in spans ≤ 5 MHz

Model-Specific Frequency Ranges
• E7401A: 9 kHz to 1.5 GHz
• E7402A: 9 kHz to 3.0 GHz (DC coupled: 30 Hz to 3.0 GHz; AC coupled: 100 kHz to 3.0 GHz)
• E7403A: 9 kHz to 6.7 GHz
• E7404A: 9 kHz to 13.2 GHz
• E7405A: 9 kHz to 26.5 GHz (DC coupled: 30 Hz to 3.6 GHz; AC coupled: 100 MHz to 3.6 GHz)

– Key Features

• Automatic EMI measurements and log sweep capability
• Built-in preamplifier for enhanced sensitivity
• Optional tracking generator on select models
• Portable, rugged construction
• SCPI programming and IVI COM driver support
• Internal 3.5-inch disk drive for data storage
• Compatible with Agilent E7415A EMI software

– Compatibility & Integration

These analyzers integrate with broadband antennas for radiated emissions assessment and couple to power/data lines via LISNs or absorbing clamps for conducted emissions evaluation. Close-field probe accessories enable detailed troubleshooting.

MPN

E7401A, E7402A, E7403A, E7404A, E7405A

Reviews

There are no reviews yet.

Be the first to review “Repair and Service Evaluation – HP/Agilent E7401A, E7402A, E7403A, E7404A, E7405A”

Your email address will not be published. Required fields are marked *

Product Condition & Availability
Repair and Service Evaluation – HP/Agilent E7401A, E7402A, E7403A, E7404A, E7405A is in excellent working condition and has been thoroughly tested for performance and reliability. We offer both new and professionally refurbished options, depending on availability and customer preference.

 

Integrated Solutions & Deployment Support
Beyond individual products, Aumictech provides end-to-end solutions for manufacturing line deployment and test station setup. Our team can assist with system integration, configuration, and equipment selection tailored to your production requirements.

Trusted Industry Experience
With over a decade of experience, Aumictech is a recognized leader in RF and optical test equipment sales and services. All units are supported by our in-house calibration and repair facility based in Downingtown, PA, ensuring technical reliability and long-term value.

Customer Commitment
We’re committed to exceptional customer service, offering a 15-day return or replacement (ROR) policy for peace of mind. Our team is always available to assist with pre- and post-sale support.

Fast Shipping & Flexible Payments
We offer rapid global shipping through FedEx, UPS, and DHL, with most orders dispatched within 1–3 business days. Multiple secure payment options are available, including PayPal, ACH, wire transfers, and major credit cards.

You May Also Like

Can't Find The Right Product? Contact Us.