Call +1 ‪(484) 841-9341‬

Service & Repair of Agilent 86142A Optical Spectrum Analyzer OSA

Agilent 86142A & 86142B Optical Spectrum Analyzer – Expert Service, Precision Repair & NIST-Traceable Calibration

We provide professional repair, maintenance, and calibration services for both the Agilent 86142A and 86142B Optical Spectrum Analyzers (OSA) — high-performance instruments widely used in DWDM, photonics, and fiber optic test environments. Designed for high dynamic range and precise wavelength measurements across a broad spectrum, these analyzers are essential tools for R&D labs, network manufacturers, and optical component testing. Our skilled technicians specialize in diagnosing and restoring these units to factory-level accuracy using advanced tools and procedures.


Full-Service Process – From Diagnosis to Certified Calibration

Thorough Diagnostics & Functional Testing
Each incoming 86142A or 86142B is subjected to a full diagnostic evaluation. We verify:

  • Wavelength accuracy over the 600–1700 nm range

  • Optical power readings and linearity

  • Trace repeatability, span sweep, and resolution bandwidth

  • Input port condition and optical alignment

  • Grating motor performance and stability

  • Front panel and display functionality

Advanced tunable lasers and calibrated reference sources are used to simulate real test conditions and capture any irregularities or failures.

Typical Problems We Repair

  • Loss of optical signal or degraded sensitivity

  • Inaccurate or drifting wavelength measurement

  • Internal grating assembly failure or misalignment

  • Burnt or worn fiber input connectors (FC/APC, SC/APC)

  • Boot-up issues, firmware freezes, or error codes

  • Damaged front panel knobs, buttons, or displays

  • Power supply instability or noisy internal fans

Component-Level Electrical & Optical Repair
We perform deep-level circuit board troubleshooting to repair or replace failed ICs, capacitors, relays, sensors, and voltage regulators. Optical assemblies are cleaned, re-aligned, and re-centered using factory-grade alignment protocols to recover signal integrity and trace stability.

Monochromator & Grating Alignment
We precisely align the internal monochromator, stepper motors, and grating control assemblies to restore optimal scan accuracy and noise floor. This ensures proper spectrum trace, peak detection, and consistent readings across sweeps.

Self-Test Diagnostics & Firmware Validation
Our repair process includes running full internal diagnostics and checking firmware integrity. Where supported, firmware is updated to improve performance and resolve legacy bugs.

NIST-Traceable Final Calibration
All units receive a certified calibration using NIST-traceable reference sources, which includes:

  • Wavelength accuracy verification with standard lasers

  • Optical power level accuracy testing

  • Noise floor and RBW validation

  • Sweep speed and span verification
    A calibration certificate is provided with detailed before/after performance metrics.


Why Choose Us for 86142A/B Repair?

  • Extensive experience with Agilent / Keysight Optical Spectrum Analyzers, including 86140A/B, 86141B, and other 86100-series models

  • Fast turnaround time – typical service completed within 1–3 business days

  • High repair success rate, even with older or non-functional units

  • Full service warranty and 15-day Right of Return

  • Global shipping support and professional-grade packaging

  • Multiple payment options: PayPal, credit card, ACH, wire


Suitable for:

  • Labs needing urgent repair of in-use 86142A or 86142B units

  • Companies with aging equipment experiencing performance degradation

  • Buyers of used OSAs needing restoration and certification

  • Service teams requiring repeatable, traceable calibration results


Get Your Agilent 86142A or 86142B Repaired by Experts

Whether your Agilent 86142A or 86142B Optical Spectrum Analyzer is showing signs of optical drift, startup errors, reduced sensitivity, or full hardware failure, we have the tools and expertise to restore it. Our blend of technical knowledge, fast service, and accurate calibration ensures your analyzer is ready for high-performance operation.

Request a quote today and let us handle the complete service lifecycle of your 86142A or 86142B unit.

Get a Quick Quote

Email: Sales@aumictech.com

Call:  +1 ‪(484) 841-9341‬

Price Starts from:

$2,480.00

Comprehensive service and repair for the Agilent 86142A Optical Spectrum Analyzer (OSA), ensuring optimal performance and accuracy. Our expert technicians provide thorough diagnostics, calibration, and component-level repairs to restore your OSA to its original factory specifications. Minimize downtime and maintain the reliability of your critical optical measurements with our professional service.

Calibration Services

Accurate measurements are critical in every lab and manufacturing environment. That’s why we offer NIST-traceable calibration. Using precision standards and certified reference equipment, our team performs a full verification of wavelength accuracy, power levels, and response time. After calibration, your instrument not only meets but often exceeds factory specifications. Every service includes a calibration certificate to support ISO and quality compliance audits.


Industry Applications

Our repair and calibration services are trusted by telecommunications providers, research labs, universities, and manufacturing plants worldwide. By maintaining tight tolerances and providing quick turnaround, Aumictech helps minimize downtime and maximize productivity. Many of our clients rely on us for scheduled preventive maintenance, ensuring instruments remain accurate during critical testing or production runs.


Cost Efficiency & On-Site Options

Unlike OEM services that often come with long lead times and high costs, Aumictech provides affordable repairs with flexible turnaround options. For large facilities or urgent needs, we also offer on-site calibration—bringing our certified equipment directly to your lab or production line. This reduces shipping delays, minimizes handling risks, and keeps your operations running smoothly without interruption.


Why Choose Aumictech

Choosing Aumictech means partnering with a dedicated repair and calibration lab focused on optical and RF test equipment. With decades of combined expertise, an extensive inventory of replacement parts, and specialized tooling for high-end instruments, we deliver reliable service at a fraction of the replacement cost. Our commitment to quality, precision, and fast turnaround makes us the trusted partner for organizations looking to extend the life and accuracy of their critical equipment.