Service & Repair of Photonetics Walics 3651HR12 Optical Spectrum Analyzer
Photonetics Walics 3651HR12 Optical Spectrum Analyzer – Professional Repair, Optical Alignment & NIST-Traceable Calibration
We provide expert repair, maintenance, and calibration services for the Photonetics Walics 3651HR12 Optical Spectrum Analyzer, a precision instrument widely used for high-resolution spectral analysis in fiber optics, photonics, and laser research. Known for its high dynamic range, narrow resolution bandwidth, and advanced wavelength accuracy, the 3651HR12 remains a critical tool in R&D labs and optical component manufacturing. If your unit is failing to boot, producing inaccurate spectral readings, or showing signs of optical or electronic drift, our technicians can restore it to peak performance using OEM-grade methods and NIST-traceable calibration.
Our Repair & Calibration Process
Complete System Diagnostics
Every 3651HR12 unit undergoes comprehensive evaluation to test:
Wavelength accuracy and spectral resolution
Optical signal detection and dynamic range performance
Sweep speed and span consistency
Internal photodetector health and gain response
Input port integrity and fiber connector condition
Control panel or remote interface (GPIB/RS232) functionality
Boot-up sequence and onboard software integrity
We use certified laser sources and test signals to replicate real-world conditions and detect subtle internal issues affecting accuracy or repeatability.
Common Problems We Repair
No optical signal or low sensitivity
Incorrect or drifting wavelength measurements
Frozen display, unresponsive UI, or boot-up failure
Faulty photodetector, amplifier, or filter circuits
Misalignment of internal optics or scanning mechanism
Damaged input fiber connectors (FC/APC, SC, etc.)
Communication interface errors (GPIB/RS232)
Internal power supply instability or noisy operation
Component-Level Repair & Restoration
We perform deep-level electronic repair, including:
Replacement of failed capacitors, op-amps, logic ICs, and regulators
Repair of photodetector boards and signal amplification stages
Restoration of sweep driver and grating control circuits
Power supply reconditioning and stabilization
Repair of damaged display modules and front panel controls
Optical Path Cleaning & Realignment
Accurate spectrum analysis depends on a precisely aligned and clean optical system. We:
Clean and realign internal lenses, mirrors, and beam splitters
Inspect and calibrate the diffraction grating and scanning mechanisms
Test and clean fiber input ports to ensure proper coupling and low insertion loss
Firmware & System Function Testing
We verify and, if needed, restore system firmware. Functional tests include:
Internal self-test sequences
Sweep calibration and span control
Output response and spectral trace validation
Remote control via GPIB or serial interface
NIST-Traceable Calibration
Following repair, each unit is recalibrated using NIST-traceable optical reference sources, including:
Wavelength calibration with certified laser sources
Spectral resolution and repeatability verification
Dynamic range and trace noise floor measurement
A detailed calibration certificate with before/after data is included with each unit.
Why Choose Us?
Extensive experience with Photonetics/Walics high-resolution OSAs
Specialized tools for legacy optics and custom photonics equipment
Fast turnaround – typically within 3–5 business days
Warranty included on all repairs and a 15-day Right of Return
Global shipping with secure packaging and customs-compliant paperwork
Multiple payment options accepted: PayPal, credit card, ACH, and wire transfer
Ideal For:
Research labs and photonics companies using the 3651HR12 for high-resolution optical spectrum analysis
Organizations restoring legacy equipment with long lead times for replacement
Resellers seeking fully restored and certified OSAs
Fiber optic professionals requiring precise, NIST-traceable wavelength accuracy
Restore Performance & Accuracy to Your Photonetics Walics 3651HR12
If your Photonetics Walics 3651HR12 Optical Spectrum Analyzer is showing signs of degradation, optical signal issues, or system errors, we’re here to help. Our expert team provides full diagnostics, precision alignment, component-level repair, and certified calibration to ensure your OSA is test-ready and performing like new.
Request a quote today to begin the repair process and restore the performance of your 3651HR12 unit.
$2,480.00
Service and repair for Photonetics Walics 3651HR12 Optical Spectrum Analyzer. Includes diagnostics, repair of faulty components, calibration, and performance verification to ensure optimal functionality.
Agilent 856x series Spectrum Analyzer Extender cable
$365.00York / PK Technology FK12 Angled Fiber Cleaver **CALIBRATED**
$2,630.00Yokogawa WT1600 Digital Power Meter
$3,080.00Yokogawa PZ4000 Power Analyzer
$4,480.00Yokogawa PX8000 Precision Power Scope, 100 MS/s, 20 Hz to 6.4 kHz
$31,480.00Yokogawa DLM5058 Mixed Signal Oscilloscope: 8-Channel, 500 MHz
$4,250.00Yokogawa DLM5054 Mixed Signal Oscilloscope: 4-Channel, 500 MHz
$4,250.00Yokogawa DLM5038 Mixed Signal Oscilloscope: 8-Channel, 350 MHz
$4,250.00Yokogawa DLM5034 Mixed Signal Oscilloscope: 4-Channel, 350 MHz
$4,550.00Yokogawa DL7200 CAN Bus Signal Analyzer W D,BS,C10
$1,279.00
Calibration Services
Accurate measurements are critical in every lab and manufacturing environment. That’s why we offer NIST-traceable calibration. Using precision standards and certified reference equipment, our team performs a full verification of wavelength accuracy, power levels, and response time. After calibration, your instrument not only meets but often exceeds factory specifications. Every service includes a calibration certificate to support ISO and quality compliance audits.
Industry Applications
Our repair and calibration services are trusted by telecommunications providers, research labs, universities, and manufacturing plants worldwide. By maintaining tight tolerances and providing quick turnaround, Aumictech helps minimize downtime and maximize productivity. Many of our clients rely on us for scheduled preventive maintenance, ensuring instruments remain accurate during critical testing or production runs.
Cost Efficiency & On-Site Options
Unlike OEM services that often come with long lead times and high costs, Aumictech provides affordable repairs with flexible turnaround options. For large facilities or urgent needs, we also offer on-site calibration—bringing our certified equipment directly to your lab or production line. This reduces shipping delays, minimizes handling risks, and keeps your operations running smoothly without interruption.
Why Choose Aumictech
Choosing Aumictech means partnering with a dedicated repair and calibration lab focused on optical and RF test equipment. With decades of combined expertise, an extensive inventory of replacement parts, and specialized tooling for high-end instruments, we deliver reliable service at a fraction of the replacement cost. Our commitment to quality, precision, and fast turnaround makes us the trusted partner for organizations looking to extend the life and accuracy of their critical equipment.