The Agilent/Keysight E1467A is a C-size, 1-slot, register-based VXI module designed for versatile signal routing and switching applications. This module features an 8×32 two-wire switching matrix configuration, offering 256 switching points. It is engineered for reliable and precise signal routing in automated test systems, data acquisition, and general-purpose switching scenarios. The E1467A utilizes latching armature relays and supports matrix expansion through a chaining cable, allowing interconnection of rows and columns on different modules to create larger matrix configurations. It shares its core switch card with the E1465A and E1466A models, with the specific terminal block determining the matrix topology.
### Technical Specifications
* **VXI Module Type:** Register-based, C-size, 1-slot
* **Matrix Configuration:** 8 Rows x 32 Columns
* **Switching Capacity:** 256 two-wire crosspoints
* **Relay Type:** Latching armature relays
* **Matrix Expansion:**
* Supports expansion to larger matrices via a chaining cable (e.g., E1466-80002) for interconnecting rows and columns
* Can be combined with other modules (E1465A, E1466A) to form larger matrices
* An 8×96 matrix can be created using three E1467A modules
* A full VXI 13-slot mainframe can accommodate up to 3072 two-wire crosspoints when using expanded configurations
* **Terminal Blocks:**
* Features QUIC easy-to-use terminal blocks
* Terminal block determines matrix topology and can be obtained separately
* Expansion terminal block options (e.g., Option 201/211) may offer quicker access and easier cable connections compared to daisy-chain cables
* **Crosstalk (Typical, 50 Ω load/source):**
* **Within a card (worst path):**
* Closed Path to Closed Path: -72 dB (<10 kHz), -51 dB (<100 kHz), -33 dB (<1 MHz)
* Open Row to Open Row: -91 dB (<10 kHz), -59 dB (<100 kHz), -43 dB (<1 MHz)
* Open Row to Open Column: -85 dB (<10 kHz), -64 dB (<100 kHz), -47 dB (<1 MHz)
* Open Column to Open Column: -92 dB (<10 kHz), -71 dB (<100 kHz), -54 dB (<1 MHz)
* **Module-to-module (represents 8x64 configuration):**
* Closed Path to Closed Path: -72 dB (<10 kHz), -51 dB (<100 kHz), -33 dB (<1 MHz)
* Open Row to Open Row: -74 dB (<10 kHz), -53 dB (<100 kHz), -38 dB (<1 MHz)
* Open Row to Open Column: -92 dB (<10 kHz), -72 dB (<100 kHz), -56 dB (<1 MHz)
* Open Column to Open Column: -82 dB (<10 kHz), -64 dB (<100 kHz), -50 dB (<1 MHz)
* *Note: Matrix expansion degrades crosstalk and bandwidth performance. Specifications are for the worst crosspoint. Guaranteed specifications may require contacting a sales representative.*
* **Switching Speed:** Less than 1 ms
* **Configuration:** Non-blocking
* **Control Interface:** GPIB, RS-232, and VXIplug&play
* **Software Compatibility:** Agilent VEE, LabVIEW, MATLAB, and C/C++
* **Power-up State:** Relays open at power-up
* **Power-down State:** Relay states are unchanged at power-down
* **Downloadable Channel Lists:** Ability to download channel lists into onboard memory
* **Maximum Voltage:** Varies depending on configuration
* **Maximum Current:** Varies depending on configuration
* **Operating Temperature:** 0°C to 55°C
* **Storage Temperature:** -20°C to 75°C
* **Humidity Range:** 0 to 95% non-condensing### Physical Characteristics* **Form Factor:** C-size, 1-slot VXI module### Compatibility* **VXI Mainframes:** Compatible with VXI mainframes, such as the E1401B 13-slot mainframe
* **Shared Switch Card:** Shares the same switch card with Agilent/Keysight E1465A and E1466A modules, allowing for flexible matrix configurations by changing terminal blocks### Documentation and Support* **Available Manuals:**
* Service Manual (E1465A/E1466A/E1467A Matrix Switch)
* User's Manual and SCPI Programming Guide (E1465A/E1466A/E1467A Relay Matrix Switch Modules)
* Technical Specifications (Data Sheet)
* **Instrument Drivers:** VXIplug&play drivers are available
* **Discontinuation Notice:** This product is noted as discontinued by Keysight, but service and support are available until the end of the worldwide support life. It may also be unavailable due to EU RoHS directive 2011/65/EU compliance.Why Choose Aumictech for the Agilent / Keysight E1467A 8 x 32 Relay Matrix Switch?
At Aumictech, we specialize in supplying high-end VXI switching equipment. Whether you need robust signal routing for complex automated test systems, precise data acquisition capabilities, or versatile general-purpose switching, our team ensures the Agilent / Keysight E1467A delivers maximum performance for your application.




















Reviews