Precision Repair and NIST-Traceable Calibration for Digital, Mixed Signal, and RF Scopes
Get a quote today Here
Introduction: Why Oscilloscope Calibration Is a Must for Precision Electronics and RF Work
Whether you’re debugging a high-speed serial bus, analyzing an RF waveform, or validating timing in mission-critical embedded systems, oscilloscopes are one of the most important tools in any electronics lab. However, an oscilloscope that isn’t properly calibrated can misrepresent voltage levels, distort timing measurements, and lead to flawed product designs or failed regulatory audits.
At Aumictech, we specialize in the repair and calibration of oscilloscopes used in industries ranging from aerospace and defense to telecom, automotive, semiconductor testing, and academic research. Our services are fully NIST-traceable, and we support oscilloscopes from all major manufacturers — including Tektronix, Keysight (Agilent/HP), LeCroy, RIGOL, GW Instek, Siglent, and Rohde & Schwarz.
Types of Oscilloscopes We Calibrate
Aumictech is equipped to calibrate a wide range of oscilloscope types, including:
Digital Storage Oscilloscopes (DSO)
- 2–4 channels
- 50 MHz to 2 GHz bandwidth
- Used for general electronics, embedded systems, and circuit debugging
Mixed-Signal Oscilloscopes (MSO)
- Logic analyzer integration
- Ideal for microcontroller and digital circuit validation
Digital Phosphor Oscilloscopes (DPO)
- High refresh rate and visual persistence
- Used in signal integrity and eye diagram analysis
RF Oscilloscopes
- 2 GHz to 33 GHz bandwidth
- Real-time spectrum analysis and transient capture
- Used in telecom, radar, and advanced R&D
USB and Modular Scopes
- PC-based platforms
- Requires software integration and interface validation
Brands and Models We Support
Tektronix
- TDS2000/3000/5000 Series
- MSO5000/MSO70000 Series
- DPO70000C Series
- MDO3000/4000 Mixed Domain Oscilloscopes
Keysight / Agilent / HP
- 3000/5000/6000 X-Series
- Infiniium 80000 Series
- DSOX/MSOX Series
- 54600 Series
Rohde & Schwarz
- RTO, RTM, RTE Series
- RTC1000/RTB2000/RTM3000
LeCroy / Teledyne
- WaveSurfer, WaveRunner, WavePro Series
- HDO and LabMaster Series
Others
- GW Instek, Siglent, RIGOL, PicoScope, B&K Precision
We also support older and legacy models no longer serviced by OEMs.
Why Oscilloscope Calibration Is Critical
Oscilloscopes age. Internal components such as ADCs, reference voltages, time base crystals, and attenuators drift over time due to temperature cycles, power-on hours, mechanical stress, and aging.
Without calibration, you may experience:
- Voltage offset errors
- Incorrect time base scaling
- Jitter in trigger timing
- Poor rise/fall time measurements
- Amplitude linearity errors
- Inaccurate frequency display
- Inconsistencies between channels
This not only affects product quality and troubleshooting accuracy but can invalidate compliance test results (e.g., FCC, CE, ISO/IEC, automotive EMI/EMC, MIL-STD testing).
Aumictech’s Oscilloscope Calibration Process
We follow a thorough, 6-step calibration workflow, combining industry best practices and NIST-traceable standards to ensure your scope is compliant and performing to spec.
Step 1: Visual and Functional Inspection
- Front-panel control check
- Display and touchscreen functionality
- Probe connector integrity
- Fan and PSU check
- I/O port diagnostics (USB, GPIB, LAN)
Step 2: Pre-Calibration Test
- Capture waveform from known source
- Measure vertical and horizontal deviation from standard
- Save user configurations and backup firmware (if needed)
- Review of internal self-test logs (many scopes log internal errors)
Step 3: Vertical Calibration (Amplitude)
- Apply calibrated voltage steps (e.g., 10 mV to 10 V)
- Validate across all ranges and channels
- Calibrate DC gain, offset, and vertical linearity
- High-frequency amplitude flatness validation (for >500 MHz scopes)
Step 4: Horizontal Calibration (Time Base)
- Inject precision clock and frequency references
- Validate time/div accuracy from ns to s range
- Calibrate jitter margin, sweep timing, and skew across channels
- Use rubidium-standard or GPS-disciplined 10 MHz source (optional)
Step 5: Trigger System and FFT Functionality
- Validate trigger sensitivity, edge detection, pulse width thresholds
- Test advanced trigger types (e.g., runt, glitch, rise/fall time)
- Validate FFT bandwidth accuracy and spectrum baseline (for RF scopes)
Step 6: Post Calibration & Documentation
- Compare results to OEM specifications
- Create and issue a NIST-traceable calibration certificate
- Include test points, deviation, technician initials, and due date
- Optional: Before/After comparison report
- 90-day service warranty
Optional Services We Offer
- Full oscilloscope repair and restoration
- Replacement of damaged BNC/SMA connectors
- Re-capping of internal power supplies (common in aging Tek/HP models)
- Firmware updates or restoration for legacy models
- Touchscreen panel replacement
- Calibration of oscilloscope probes (passive, active, differential)
Calibration Interval Recommendations
- General lab use: every 12 months
- Mission-critical or QA testing: every 6 months
- Post-repair or reconfiguration: immediate calibration required
- Pre-audit: ensure calibration within audit window
We offer automatic annual reminders and multi-instrument bundle plans for labs and businesses.
Who Relies on Our Oscilloscope Calibration?
Industry | Use Case |
---|---|
Telecom | Transceiver, fiber, and RF signal analysis |
Aerospace/Defense | Embedded systems, radar, sensor validation |
Semiconductor | Chip design, verification, and package-level debugging |
Automotive | ECU testing, CAN/LIN/FlexRay timing |
R&D Labs | Research, prototyping, and waveform modeling |
Universities | Lab equipment for electrical engineering students |
Calibration Labs | Reseller-level recertification for used gear |
Why Choose Aumictech?
- U.S.-based lab with professional equipment and clean handling
- Over a decade of experience in electronics and RF calibration
- Support for legacy equipment no longer covered by OEMs
- Affordable flat-rate pricing and no-nonsense quoting
- Rapid 3–5 business day turnaround (expedited available)
- Local pickup & delivery in PA/NJ/NY
- Repair + calibration under one roof
Testimonials
“Our Infiniium scope was failing eye diagram tests. Aumictech calibrated the time base and amplitude errors, and now it’s back to spec for our compliance bench.”
– Senior Engineer, High-Speed Digital Design Lab
“We sent in 8 Tek scopes from our university. They came back faster than our OEM quote, fully certified, and with clean, organized paperwork for each unit.”
– Lab Director, Engineering School, Philadelphia
Request a Free Oscilloscope Calibration Quote Today
If your oscilloscope is out of spec or overdue for calibration, don’t wait. Contact Aumictech today and get the precision you need — fast and professionally done.
Email: sales@aumictech.com
Website: www.aumictech.com
Final Thoughts
Oscilloscopes are the eyes of your electronics lab. But even the best scope is only as reliable as its last calibration. Don’t trust your designs, tests, or compliance audits to a misaligned instrument. Let Aumictech ensure accuracy, compliance, and confidence — one waveform at a time.