The Acopian K20D50 is a regulated DC power supply engineered for industrial and laboratory applications demanding precision voltage stability and reliable current delivery. It combines electronic current limiting with automatic recovery protection, transient response of 50 microseconds, and remote voltage sensing to maintain output regulation across the load. The unit accommodates single-phase AC input of 105–125 VAC at 50–400 Hz and features floating or dual output configurations with temperature coefficients as low as 0.015%/°C.
– Technical Specifications
• Input Power: 105–125 VAC, 50–400 Hz, single phase
• Output Configuration: Floating single output (either terminal may be grounded or floated to 300 V above ground) or positive/common/negative dual output
• Temperature Coefficient: 0.015%/°C (single output, typical); 0.02%/°C (dual output, typical)
• Operating Temperature: –20 to +71°C (linear models); 0 to +71°C (switching models)
• Storage Temperature: –55 to +85°C (linear); –40 to +85°C (switching)
• Humidity: 20–80% R.H., non-condensing
• Transient Response (no-load to full-load): 50 microseconds
• Input/Output Isolation: 500 Vdc voltage rating; 100 MΩ resistance; 100 pF capacitance
• Switching Frequency: 20 kHz minimum
• Protection: Electronic current limiting with automatic recovery; thermal protection with automatic reset
– Key Features
• Remote voltage sensing standard for load regulation
• 10-turn precision controls with locking vernier dials for voltage and current adjustment
• Screw terminals for DC output connections
• Extruded aluminum construction rated for standard 19″ RETMA cabinet racks
• Light gray enamel front panel finish
• Thermal and overload protection with automatic recovery
– Typical Applications
Precision powering of laboratory test equipment, industrial control systems, and electronic apparatus requiring stable, regulated DC output with fast transient response and integrated current limiting.
– Compatibility & Integration
Mounts in standard 19″ RETMA racks, chassis, or benchtop environments. Optional DIN rail mounting kit (EB35DIN) available. UL Listed time-delay fuses specified for 120 V input models. Input transient suppression recommended for noisy AC supplies.




















Reviews
There are no reviews yet.