The Aeroflex IFR DT200 Databus Analyzer is a portable, battery-operated diagnostic instrument for capturing, analyzing, and simulating ARINC 429 and Commercial Standard Digital Bus (CSDB) avionics databus traffic. Field and laboratory technicians use the DT200 to validate systems, detect faults, and support integration tasks across dual-mode operation. The instrument displays data in hexadecimal, binary, or engineering units, with onboard functions including freeze, scroll, clear, and graphic time-plot rendering. Recording capacity spans approximately 20 minutes for dual-label configurations at 1 word per second, with playback supporting graphics plots, hex lists, or DC output. Battery runtime extends to 6 hours on internal rechargeable cells, enabling extended field deployment.
– Technical Specifications
ARINC 429 Receive:
• Bus frequency: 12.5 kHz to 100 kHz (selectable)
• Input voltage: +6.5 VDC to +13.5 VDC (A to B)
• Input impedance: 12.0 kΩ
• Maximum labels: 255 per SDI value
• Breakpoint conditions: EQ, NEQ, OR, GT, LT, /GT/, /LT/
• Break history: 85 words per label; 16 labels maximum
• Record intervals: 10 ms to 5 s (selectable)
• Record capacity: ~20 minutes (2 labels, 1 word/s)
ARINC 429 Transmit:
• Bus frequency: 12.5 kHz to 100 kHz (selectable)
• Output voltage: +3.0 to +5.0 VDC (A to B)
• Output impedance: 100 Ω
• Maximum transmit labels: 16
• D/A range: +5.0 VDC, 8 bits
• D/A scaling: 100%, 50%, or 12.5% of digital word
• Trigger pulse: +5 VDC, 0.5 ms
• Burst mode: 1–99 outputs at selectable rate
CSDB (Commercial Standard Digital Bus):
• Bus frequency: 12.5 kHz or 50 kHz (selectable)
• Output voltage: +3.0 to +5.0 VDC (A to B)
• Output impedance: 100 Ω
• High and low-speed receive/transmit supported
• Data format per Collins Doc. 523-0772774-00411R
General:
• Display: 1.7″ × 6.0″ LCD; 8 lines × 40 characters or 64 × 256 dot graphics
• Power: 7.0 W @ 110 VAC/60 Hz; 8.4 W @ 28 VDC or battery
• Battery operation: Up to 6 hours
• Front panel dimming control
– Key Features
• Dual-mode operation: ARINC 429 and CSDB
• Multi-format data display: hexadecimal, binary, engineering units
• Graphic time-plot capability for transient analysis
• Flexible record intervals and extended playback options
• Programmable breakpoint triggering with conditional logic
– Typical Applications
• Avionics system validation and fault isolation
• Flight test and laboratory data recording
• Databus simulation and protocol verification
• Integration testing of ARINC 429 and CSDB networks
– Compatibility & Integration
The DT200 operates with standard avionics ARINC 429 and CSDB interfaces, supporting both receive and transmit modes across specified frequency and voltage ranges.