The Agilent/Keysight 6626A is a four-output linear DC power supply engineered for precision test environments requiring stable, low-noise power delivery. Each output operates independently with dual-range capability, offering two 25 W outputs and two 50 W outputs to accommodate diverse voltage and current requirements. GPIB programmability enables automated control and monitoring, while 14-bit resolution ensures repeatable voltage and current settings across test sequences.
– Technical Specifications
Output Configuration
• Four independent linear outputs: two at 25 W, two at 50 W
• Dual-range operation per output for voltage and current flexibility
• 25 W outputs: 0–7 V / 0–15 mA (low-range); 0–50 V / 0–500 mA (high-range)
• 50 W outputs: 0–16 V / 0–200 mA (low-range); 0–50 V / 0–1 A or 0–16 V / 0–2 A (high-range)
Programming & Readback Accuracy (25°C ±5°C)
• Voltage: ±0.016% + 1.5–53 mV (25 W outputs); ±0.016% + 10 mV (50 W outputs, high-range)
• Current: ±0.04% + 15 µA to 500 µA depending on output and range
• Readback: 0.016% voltage; 0.03% current
• Resolution: 14-bit for both programming and readback
Output Quality
• Ripple & noise (20 Hz–20 MHz): 500 µV RMS, 3 mV peak-to-peak; 0.1 mA RMS current
• Load regulation: 0.5 mV / 0.005 mA
• Line regulation: 0.5 mV / 0.005 mA
– Key Features
• GPIB interface for remote control and data logging in automated test systems
• Extensive DUT protection circuitry
• Low-noise linear topology suitable for sensitive analog circuits
• 3U form factor: 16.75 in × 5.22 in × 19.6 in
– Typical Applications
Research and development, manufacturing test, quality assurance, and bench characterization of analog and mixed-signal devices requiring multi-voltage supply rails with tight regulation and low output noise.
– Compatibility & Integration
Standard GPIB connectivity enables integration with existing test automation frameworks. Safety Class 1 with protective earth terminal for grounded operation. Rated for indoor Installation Category II, Pollution Degree 2 environments; 0–55°C operating range; up to 95% relative humidity and 2000 m altitude.



























Reviews