Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST Calibration Available on demand.

Service Support

Service plans available for the products’ durability

FAST REPAIRS

Overnight repairs available for selected products

Software Updates 

Staying up-to-date with lastest software updates.

Lifetime Support by Aumictech
Free OEM-grade Calibration
Fastest turnaround times

Product Condition & Availability
Agilent / Keysight 83206A TDMA Cellular Adapter is in excellent working condition and has been thoroughly tested for performance and reliability. We offer both new and professionally refurbished options, depending on availability and customer preference.

 

Agilent / Keysight 83206A TDMA Cellular Adapter

SKU: 83206ACategories: Wireless Communication Testers
30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • 100% Verified & Tested Equipment
  • Rental Units Available

The Agilent/Keysight 83206A TDMA Cellular Adapter is designed for testing and evaluating TDMA (Time Division Multiple Access) cellular communication systems. It provides a convenient interface for connecting test equipment to cellular devices, enabling accurate and reliable measurements of signal quality, modulation, and other key performance parameters. Ideal for engineers and technicians working on cellular network infrastructure and mobile device development.

Request Repair
Product Starting From:

$85.30

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 83206A
Equipment info

The Agilent/Keysight 83206A TDMA Cellular Adapter is a specialized module designed to enhance the measurement capabilities of the Agilent/Keysight 8920B RF Communications Test Set. Its primary function is to provide TDMA (Time Division Multiple Access) capabilities, specifically for DAMPS (Digital Advanced Mobile Phone System) IS-54 and DCCH (Digital Control Channel) IS-136 cellular standards. The adapter acts as an interface, enabling the 8920B Test Set to perform comprehensive testing and evaluation of TDMA cellular communication systems and devices. It integrates essential functions such as a π/4 DQPSK signal generator, a π/4 DQPSK modulation analyzer, a data source, and a Bit Error Rate (BER) analyzer, crucial for accurate and reliable signal quality, modulation, and performance parameter measurements in TDMA networks. The 83206A is a successor to the 83201B TDMA cellular adapter, offering enhanced digital control channel test features for more thorough characterization of DCCH phones.

### Technical Specifications

**General Functionality**
* **Purpose:** Adds TDMA DAMPS/DCCH (IS-136) mobile measurement capability to the Agilent 8920B RF Communications Test Set.
* **Modulation Support:** Primarily focused on π/4 DQPSK signal generation and analysis.
* **Standards Supported:** DAMPS (IS-54), DCCH (IS-136), and TIA/EIA-136.
* **Integrated Features:**
* π/4 DQPSK Signal Generator
* π/4 DQPSK Modulation Analyzer
* Data Source
* Bit Error Rate (BER) Analyzer
* **Replaces:** Agilent 83201B TDMA cellular adapter (8920B-500).

**TDMA Signal Generator Specifications**
* **Frequency Range:** 824 MHz to 894 MHz.
* **Output Level Range:**
* RF IN/OUT: -22 dBm to -127 dBm.
* DUPLEX OUT: +4 dBm to -127 dBm.
* **Residual Error Vector Magnitude (EVM):**
* < 3.0% * < 1.3% (This value appears in some sources in relation to the analyzer, but may also apply to generator performance under certain conditions or refer to residual performance). * **Residual Phase Error:** < 2.0°. * **Residual Magnitude Error:** < 2.6%. * **IQ Origin Offset:** <-30 dBc within ±15° C of last calibration. * **Frequency Error:** ±4 Hz plus reference accuracy.**TDMA Analyzer Specifications** * **Frequency Range:** 800 MHz to 900 MHz. * **Input Level Range:** * RF IN/OUT: 1 mW to 60 W (0 to +47.8 dBm). * ANT IN: -36 dBm to +16 dBm. * **Input Frequency Setting Error:** 1 kHz. * **Frequency Error Accuracy:** ±2.5 Hz plus reference accuracy. * **Residual Error Vector Magnitude (EVM):** < 1.3%. * **Error Vector Magnitude (EVM) Measurement Accuracy:** ±0.4% +2% of reading. * **Residual Phase Error:** < 1.0°. * **Residual Magnitude Error:** < 0.9%. * **IQ Origin Offset Accuracy:** ±0.5 dB for values greater than -40dBc.**Physical Specifications** * **Weight:** 4.5 kg (10 lbs) net. * **Dimensions:** 62 H × 330 W × 456 D mm (2.4 H × 13 W × 18 D in).**Environmental Specifications** * **Operating Temperature Range:** 0° to 55° C. * **Power Requirements:** 100 to 240 V; 50 to 60 Hz; 100 VA. * **Leakage:** Meets CISPR 11 for conducted and radiated interference.### Compatibility* **Primary Host Instrument:** Agilent/Keysight 8920B RF Communications Test Set. * **Companion Software/Firmware:** Requires familiarity with the Keysight 8920B User's Guide.### Documentation* **User's Guide:** Keysight Technologies 83206A User's Guide (dated 2001-09-06) is available. * **Related Documentation:** * 8920B RF Communications Test Set User's Guide. * 8920A/B Application Handbook. * Keysight Technologies 83236B PCS Interface (mentioned in relation to setup).Why Choose Aumictech for the Agilent / Keysight 83206A TDMA Cellular Adapter? At Aumictech, we specialize in sourcing and supplying high-end RF test and measurement equipment. Whether you need to enhance your existing Agilent/Keysight 8920B with advanced TDMA capabilities, ensure accurate testing of DAMPS and DCCH devices, or require a reliable adapter for cellular network infrastructure development, our team ensures the Agilent / Keysight 83206A TDMA Cellular Adapter delivers maximum performance for your application.

MPN

83206A

Reviews

There are no reviews yet.

Be the first to review “Agilent / Keysight 83206A TDMA Cellular Adapter”

Your email address will not be published. Required fields are marked *

Integrated Solutions & Deployment Support
Beyond individual products, Aumictech provides end-to-end solutions for manufacturing line deployment and test station setup. Our team can assist with system integration, configuration, and equipment selection tailored to your production requirements.

Trusted Industry Experience
With over a decade of experience, Aumictech is a recognized leader in RF and optical test equipment sales and services. All units are supported by our in-house calibration and repair facility based in Downingtown, PA, ensuring technical reliability and long-term value.

Customer Commitment
We’re committed to exceptional customer service, offering a 15-day return or replacement (ROR) policy for peace of mind. Our team is always available to assist with pre- and post-sale support.

Fast Shipping & Flexible Payments
We offer rapid global shipping through FedEx, UPS, and DHL, with most orders dispatched within 1–3 business days. Multiple secure payment options are available, including PayPal, ACH, wire transfers, and major credit cards.

You May Also Like

Can't Find The Right Product? Contact Us.