The Agilent/Keysight 83496B is an optical/electrical clock recovery module that extracts clock signals from data streams with ultra-low residual jitter, enabling precise eye-mask and jitter measurements on the Keysight 86100C Digital Communications Analyzer. Supporting continuous data rates from 50 Mb/s to 14.2 Gb/s and delivering less than 300 fs RMS residual jitter at 10 Gb/s, the module accommodates both electrical and optical inputs across single-mode and multi-mode fiber. Its phase noise analysis capability and selectable loop bandwidth architecture—from 30 kHz fixed operation to 10 MHz tunable with Option 300—address demanding metrology applications where signal integrity and measurement fidelity are critical.
– Technical Specifications
Data Rate & Performance
• Continuous tuning: 50 Mb/s to 14.2 Gb/s (Option 200); 50 Mb/s to 7.1 Gb/s (Option 100); 7.1 Gb/s to 14.2 Gb/s (Option 201)
• Residual jitter (output clock): < 300 fs RMS characteristic at 10 Gb/s
• Output random jitter: < 3 mUI (700 fs) at 50–4.2 Gb/s; < 700 fs at 4.2–7.2 Gb/s; < 500 fs at 7.2–11.4 Gb/s
• Acquisition range: ± 5000
Electrical Interface (Option 100)
• Inputs/Outputs: Single-ended or differential, 3.5 mm (m) connectors
• Minimum input level: 75 mVpp
• Maximum input: 6 Vpp differential, 3 Vpp single-ended (AC coupled)
• Input return loss: 22 dB minimum (DC to 12 GHz); 16 dB minimum (12–20 GHz)
Optical Interface (Option 101)
• Fiber types: 9/125 µm single-mode, 62.5/125 µm multi-mode
• Wavelength ranges: Single-mode 1260–1360 nm, 1490–1600 nm; Multi-mode 830–860 nm, 1260–1360 nm
• Minimum optical modulation amplitude: -11 dBm (1310/1550 nm single-mode); -10 dBm (1310 nm multi-mode); -8 dBm (850 nm multi-mode)
• Insertion loss: 2.5 dB single-mode, 3 dB multi-mode
• Internal splitter ratio: 20/80 single-mode, 30/70 multi-mode
Loop Bandwidth
• Standard: 270 kHz or 1.5 MHz; fixed at 30 kHz below 1 Gb/s (without Option 300)
• Option 300: Tunable 15 kHz to 10 MHz continuously, ± 30% accuracy
– Key Features
• Phase noise analysis of clock or data signals
• High gain tracking for spread-spectrum signals
• Dual input/output configuration for flexible integration
• Selectable bandwidth for loop control optimization
– Typical Applications
• High-speed serial link characterization and compliance testing
• Jitter decomposition and eye-diagram analysis
• Optical transceiver validation across telecom and datacom wavelengths
– Compatibility & Integration
Designed as a module for the Keysight 86100C Digital Communications Analyzer, supporting both electrical and optical signal recovery within a unified measurement platform.



























Reviews