The Agilent/Keysight N4877A is a clock data recovery and demultiplexer module for high-speed digital communication testing from 50 Mb/s to 32 Gb/s. It recovers clock signals from data streams when unavailable from the device under test, or cleans up clock signals degraded by excessive jitter. The module includes a 1:2 demultiplexer for sub-rate BERT testing and integrates with Keysight’s J-BERT and ParBERT receiver test solutions.
– Technical Specifications
• Data Rate Range: 50 Mb/s to 32 Gb/s; option extends to 16.5 Gb/s for standards including 16GFC, USB 3.0, SATA, SAS, and PCIe Gen4
• Phase-Locked Loop: Tunable loop bandwidth to 20 MHz with selectable peaking for industry standard compliance
• Jitter Performance: Auxiliary clock output with residual jitter as low as 100 fs RMS
• Demultiplexer: Built-in 1:2 demultiplexer with software-controlled, swappable outputs (even and odd bits)
• Data Input Connectors: 2.4 mm (f)
• Clock/Data Output Connectors: SMA
• Control Interface: USB for PC connection and graphical user interface
– Key Features
• Clock recovery from data streams when DUT clock output is unavailable
• Phase-Locked Loop clean-up function for clocks with excessive intrinsic jitter
• Low residual jitter enables accurate transmitter measurements
• Software-controlled demultiplexer output selection simplifies receiver testing workflows
– Typical Applications
• receiver and transmitter characterization
• High-speed device receiver testing with J-BERT and ParBERT solutions
• Golden PLL operation for stimulus-response testing with precision jitter sources (86100CU-400, 86100DU-400)
• Transmitter waveform analysis
• Computer, datacom, and communication standards validation
– Compatibility & Integration
• Compatible with Keysight J-BERT (N4903B) and ParBERT receiver test solutions
• Integrates with 86100 Digital Communications Analyzer
• Configurable as jitter receiver for PLL stimulus-response testing with 86100CU-400 or 86100DU-400 software
• Integrates into multi-channel BERT systems including 81250 ParBERT for full-rate sampling to 27 Gb/s
• Cable kit N4915A-016 maintains phase relationship between recovered clock and demultiplexed data
• Compatible with pick-off kits such as N915A-015 (50 GHz bandwidth)