The Amrel LPS-302 is a 60 W linear programmable DC power supply built for electronic testing, development, and production environments. It delivers adjustable voltage and current outputs across dual ranges with exceptional stability—1 mVrms noise and 10 mVp-p ripple (20 Hz–2 MHz) ensure clean power for sensitive circuits. The unit combines precision voltage control (±0.2% accuracy, 10 mV resolution) with stable current regulation (±0.5% accuracy, 1 mA resolution) and supports both local front-panel operation and remote RS-232C command via ASCII protocol at 2400 baud.
– Technical Specifications
Output Power & Voltage
• 60 W total output power
• Dual-range voltage: 0–15 V (High Range) / 0–30 V (Low Range)
• Voltage accuracy: ±(0.2% of reading + 2 digits)
• Setting resolution: 10 mV
• Line regulation: 1 mV; Load regulation: 2 mV
• Noise: 1 mVrms; Ripple (20 Hz–2 MHz): 10 mVp-p
• Temperature coefficient: 100 ppm/°C typical
Output Current
• Dual-range current: 0–4 A (High Range) / 0–2 A (Low Range)
• Current accuracy: ±(0.5% of reading + 5 digits)
• Setting resolution: 1 mA
• Line regulation: 15 mA; Load regulation: 5 mA
• Noise: 1 mArms; Ripple: 5 mAp-p
• Temperature coefficient: 200 ppm/°C typical
• Transient response: 100 µs typical
Environmental & Physical
• Operating temperature: 0 °C to 40 °C
• Storage temperature: –40 °C to 70 °C
• Operating humidity: Up to 80% RH
• Dimensions: 8.4″ W × 5.2″ H × 15.7″ L
• Weight: 12 lbs
• Cooling: Forced air
• Display: 16 × 2 LCD with backlight
– Key Features
• Dual-range voltage and current capability for flexible load matching
• Low-noise linear architecture with ±240 V common-mode voltage rating
• 16 × 2 LCD display and front-panel keypad for intuitive operation
• RS-232C interface (optional/standard on certain LPS300 models) for automated test sequences
• Tight load and line regulation for stable sourcing under dynamic conditions
– Typical Applications
• Component characterization and quality assurance testing
• Circuit development and prototype validation
• Production burn-in and functional test
• Bench-top research and educational labs
– Compatibility & Integration
RS-232C remote control operates at 2400 baud with N81 framing and ASCII command set (case-insensitive). Complete operation and service manuals covering the LPS300 series (LPS 301–305) provide detailed setup, troubleshooting, and calibration guidance.