The BK Precision 9141 is a versatile triple-output, multi-range DC power supply designed for demanding B2B applications. It offers three independent, floating output channels, each capable of delivering up to 100W of clean power with low ripple and noise characteristics, totaling 300W. This unit is housed in a compact 2U half-rack form factor, making it suitable for both benchtop use and integration into test systems. The multi-ranging capability allows for flexible output configurations, and channels can be combined to achieve higher voltage or current outputs as needed. Advanced features include list mode programming for complex test sequences, channel coupling and tracking, configurable delays, and direct data logging to a USB flash drive. It also includes adjustable voltage and current slew rates, along with comprehensive protection features such as Over Voltage Protection (OVP), Over Current Protection (OCP), and Over Temperature Protection (OTP). For connectivity, the BK Precision 9141 supports USB (USBTMC-compliant) and LXI compliant LAN, with a GPIB option available for enhanced system integration. Compatibility with LabVIEW, IVI-C, and IVI.NET drivers simplifies development and integration into automated test environments.
### Technical Specifications
**General**
* **Model:** BK Precision 9141
* **Series:** 9140 Series
* **Manufacturer:** B&K Precision
* **Type:** Triple Output, Multi-Range DC Power Supply
* **Total Power Output:** 300W
* **Form Factor:** 2U Half-Rack
* **Mounting Type:** Bench Top / Rack Mountable (RK2US Rack Mount Kit available as optional accessory)
**Electrical Output Specifications (Per Channel)**
* **Number of Outputs:** 3 Independent, Floating Channels
* **Maximum Output Voltage:** 60 VDC
* **Maximum Output Current:** 4 A
* **Maximum Power per Channel:** 100 W
* **Output Voltage Resolution:** 1 mV
* **Output Current Resolution:** 1 mA
* **Voltage Regulation (Line):** 0.01% + 3mV
* **Voltage Regulation (Load):** 0.01% + 3mV
* **Current Regulation (Line):** 0.01% + 3mA
* **Current Regulation (Load):** 0.01% + 3mA
* **Voltage Ripple and Noise:** ≤2mVrms, ≤10mVpp (typically down to 1mVrms)
* **Transient Response Time:** 10 ms (for load change 50-100%)
* **Rise Time:** 10 ms to 20 ms (from 10% to 90% of total voltage excursion)
* **Fall Time:** 10 ms to 20 ms (from 10% to 90% of total voltage excursion)
* **Remote Sense Compensation:** 1 V
**Combined Output Capabilities**
* **Maximum Combined Output Voltage:** Up to 180 V (by combining outputs)
* **Maximum Combined Output Current:** Up to 24 A (by combining outputs, model dependent)
**Protection Features**
* **Over Voltage Protection (OVP):** Yes
* **Over Current Protection (OCP):** Yes
* **Over Temperature Protection (OTP):** Yes
* **Key Lock:** Yes
* **Remote Inhibit:** Supported
* **Voltage Fault:** Supported
**Programming and Control**
* **Programmable:** Yes
* **List Mode Programming:** Advanced, easy-to-use
* **Channel Coupling:** Yes
* **Channel Tracking:** Yes
* **Configurable Delays:** Yes
* **Adjustable Slew Rates:** Voltage and Current
* **Command Response Time:** 10 ms (typical)
**Data Logging and Interface**
* **Direct Data Logging:** To USB flash drive
* **Interfaces:**
* USB (USBTMC-compliant and virtual COM)
* LAN (LXI compliant, device specification 2016)
* GPIB (Optional, available on 9141-GPIB model)
* **Web Server:** Built-in for remote configuration, monitoring, and control via web browser.
* **Drivers:** LabVIEW™, IVI-C, IVI.NET provided
* **Operating Software:** Included (available for download)
**Display**
* **Type:** 4.3″ LCD
* **Display Features:** Digital display for voltage and current
**Electrical Input Specifications**
* **Input Voltage:** 100 VAC to 240 VAC ±10%
* **Input Frequency:** 47 Hz to 63 Hz
* **Maximum Rated Input Power:** 500 VA
* **Power Factor:** 0.98 @ 115 VAC, 0.94 @ 230 VAC
**Physical Specifications**
* **Dimensions (W x H x D):** 8.4” x 3.5” x 13” (213 x 88 x 330 mm)
* **Weight:** 11 lbs (5 kg)
**Environmental and Compliance**
* **Operating Temperature:** 32 °F to 104 °F (0 °C to 40 °C)
* **Storage Temperature:** 14 °F to 158 °F (-10 °C to 70 °C)
* **Regulatory Compliance:**
* Safety: Low Voltage Directive (LVD) 2014/35/EU, EN61010-1:2010, cTUVus certification mark (fulfills US UL 61010-1:2012 and Canadian CAN/CSA-C22.2 NO. 61010-1-12 safety standards)
* Electromagnetic Compatibility (EMC): EMC Directive 2014/30/EU, EN61326-1:2013
* **Category Rating:** Intended for CATEGORY II mains power environment.
**Standard Accessories**
* Power cord
* Test report & certificate of calibration
**Optional Accessories**
* Rack Mount Kit (RK2US)
Why Choose Aumictech for the BK Precision 9141?
At Aumictech, we specialize in supplying high-end power supply equipment. Whether you need reliable multi-channel power for complex testing, precise voltage and current control for sensitive circuits, or seamless integration into automated test systems, our team ensures the BK Precision 9141 delivers maximum performance for your application.