Burleigh 1500S Wavemaster Optical Wavelength Meter

SKU: 1500SCategories: Metrology Equipment
Brand: Burleigh
30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • 100% Verified & Tested Equipment
  • Rental Units Available

The Burleigh 1500S is a high-resolution optical profiler designed for non-contact surface metrology. It utilizes scanning white light interferometry (SWLI) to capture detailed 3D surface topography with nanometer-scale vertical resolution. Ideal for characterizing surface roughness, step heights, and critical dimensions on a variety of materials.

Request Repair
Product Starting From:

$2,100.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 1500S
Equipment info

The Burleigh WA-1500 is a laser wavelength meter designed for precise measurement of continuous wave (CW) laser wavelengths. It utilizes a scanning Michelson interferometer and an internal HeNe laser wavelength standard for absolute wavelength determination by comparing interference fringe patterns. The instrument offers high accuracy and reliability for applications in laser research, development, and manufacturing.

### Technical Specifications

* **Wavelength Range:**
* Near Infrared (NIR): 600 – 1800 nm
* Visible (VIS): 400 – 1100 nm
* Infrared (IR): 1.5 – 4 µm
* **Accuracy:**
* ± 0.2 ppm (parts per million), which translates to ± 0.0002 nm at 1000 nm, when laser spectral bandwidth is less than 1 GHz (FWHM)
* ± 50 MHz
* **Display Resolution:** 0.0001 nm
* **Maximum Input Level (NIR):** 2 mW
* **Optical Input:**
* 9/125 µm Single-Mode fiber
* Supports fiber-optic and free-space inputs
* **Interfaces:**
* RS-232 (bidirectional)
* GPIB
* **Analog Output:** Provides a voltage proportional to the deviation from a specified wavelength setpoint, enabling monitoring and feedback control
* **Environmental Corrections:** Features automated corrections for environmental factors
* **Interferometer Type:** Scanning Michelson interferometer
* **Internal Standard:** Built-in HeNe laser wavelength standard
* **Operating Modes:**
* Averaging mode with user-selectable number of samples (2 to 50)
* Wavelength setpoint functionality for deviation measurement and analog output control
* **Front Panel Control:** Lockable to prevent manual input, allowing for remote computer control

### Physical Characteristics

* **Design:** Compact and portable design suitable for laboratory and field applications

### Interfaces and Control

* **Remote Operation:** RS-232 and GPIB interfaces facilitate remote control
* **Data Output:** Analog output for wavelength monitoring and feedback control
* **Software Control:** Driver modules are available for integration with control software (e.g., instrumental.drivers.wavemeters.burleigh.WA_1000)

### Compatibility

* **Laser Types:** Designed for Continuous Wave (CW) lasers
* **Wavelength Ranges:** Available in three versions for different operational ranges: Visible (VIS), Near-Infrared (NIR), and Infra-Red (IR)

Why Choose Aumictech for the Burleigh WA-1500?
At Aumictech, we specialize in supplying and servicing high-end laser metrology equipment. Whether you need precise wavelength measurement for R&D, critical quality control in manufacturing, or reliable performance for laboratory applications, our team ensures the Burleigh WA-1500 delivers maximum performance for your application.

MPN

1500S

Reviews

There are no reviews yet.

Be the first to review “Burleigh 1500S Wavemaster Optical Wavelength Meter”

Your email address will not be published. Required fields are marked *

Product Condition & Availability
Burleigh 1500S Wavemaster Optical Wavelength Meter is in excellent working condition and has been thoroughly tested for performance and reliability. We offer both new and professionally refurbished options, depending on availability and customer preference.

 

Integrated Solutions & Deployment Support
Beyond individual products, Aumictech provides end-to-end solutions for manufacturing line deployment and test station setup. Our team can assist with system integration, configuration, and equipment selection tailored to your production requirements.

Trusted Industry Experience
With over a decade of experience, Aumictech is a recognized leader in RF and optical test equipment sales and services. All units are supported by our in-house calibration and repair facility based in Downingtown, PA, ensuring technical reliability and long-term value.

Customer Commitment
We’re committed to exceptional customer service, offering a 15-day return or replacement (ROR) policy for peace of mind. Our team is always available to assist with pre- and post-sale support.

Fast Shipping & Flexible Payments
We offer rapid global shipping through FedEx, UPS, and DHL, with most orders dispatched within 1–3 business days. Multiple secure payment options are available, including PayPal, ACH, wire transfers, and major credit cards.

You May Also Like

Can't Find The Right Product? Contact Us.