California Instruments 3091 Harmonics and Flicker Analyzer

SKU: 3091Categories: Other Test Equipment
30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • 100% Verified & Tested Equipment
  • Rental Units Available

The California Instruments 3091 is a precision AC power source designed for testing and simulating various AC power conditions. It provides stable and accurate voltage and frequency output, ideal for product testing, R&D, and compliance testing applications.

Request Repair
Product Starting From:

$3,800.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 3091
Equipment info

The California Instruments 3091LD is a multi-mode AC electronic load designed for precise testing of AC power generation equipment, including Uninterruptible Power Supplies (UPS) and AC sources. It is also suitable for testing active or passive current-carrying devices such as switches, circuit breakers, fuses, connectors, and power semiconductors. The 3091LD can emulate a wide range of AC load conditions, including high crest factor and variable power factor loads, to simulate real-world scenarios and enhance product reliability. It offers flexible solutions for various AC power test applications and can be configured for higher power or three-phase operation by combining a master unit with auxiliary units.

### Technical Specifications

* **Power Dissipation:**
* 3000 W @ 0-37° C
* 2400 W @ 38-50° C
* Max. Peak Power: 13 kW (up to 20% duty cycle)
* **Voltage:**
* Range: 50 to 350 VRMS
* Max. Peak Voltage: 500 VPEAK
* **Current:**
* Range: 0 to 30 ARMS
* Max. Peak/Surge Current: 90 APEAK Surge; 300 APEAK for 50 ms
* **Frequency:**
* Range: 45 to 440 Hz
* **Operating Modes:**
* **Constant Power (CP):** Emulates loads such as switching power supplies.
* **Constant Resistance (CR):** Emulates conventional resistive loads, programmable from 2.5 to 1000 Ohms.
* **Constant Current (CC):** Provides a constant current load, suitable for voltage regulation testing. Range: 0 to 30 ARMS. Accuracy: 0.2% of full scale. Resolution: 0.05% of full scale.
* **Constant Voltage (CV):** Emulates a shunt regulator load, for testing current source products. Range: 50 to 350 VRMS. Accuracy: 0.2% of full scale. Resolution: 0.05% of full scale.
* **Short Circuit (SC):** Provides a short condition to test EUT’s short circuit protection. Max. Surge current: 300 APEAK for up to 50 ms.
* **Crest Factor:**
* Range: 1.4142 to 4.0 (limited to 90 Apeak)
* Accuracy: 1% of full scale
* **Power Factor:**
* Range: 0 to 1 lead or lag (limited by Crest Factor settings)
* Accuracy: 1% of full scale
* **Measurements:**
* Built-in measurement functions to eliminate the need for external test equipment.
* **Interfaces:**
* IEEE-488 (GPIB) – Standard
* RS232C
* **Control:**
* Menu-driven front panel for direct operation.
* Remote control via IEEE-488 and RS232C interfaces using SCPI protocol.
* Windows™ Graphical User Interface (GUI) for expanded measurement and display capabilities, with saving and printing of test results.
* **Master/Auxiliary Configuration:**
* A master 3091LD unit can be combined with one or more auxiliary 3091 units for higher power or three-phase applications. The master unit consolidates measurements for system integration.
* **Physical:**
* Dimensions: 8.75” (222 mm) H x 16.88” (429 mm) W x 25” (635 mm) D
* Weight: 74 lbs / 34 Kg

Why Choose Aumictech for California Instruments 3091LD?
At Aumictech, we specialize in supplying high-end AC electronic load equipment. Whether you need precise simulation of real-world AC power conditions, robust testing of power generation equipment, or reliable emulation of complex load scenarios, our team ensures the California Instruments 3091LD delivers maximum performance for your application.

MPN

3091

Reviews

There are no reviews yet.

Be the first to review “California Instruments 3091 Harmonics and Flicker Analyzer”

Your email address will not be published. Required fields are marked *

Product Condition & Availability
California Instruments 3091 Harmonics and Flicker Analyzer is in excellent working condition and has been thoroughly tested for performance and reliability. We offer both new and professionally refurbished options, depending on availability and customer preference.

 

Integrated Solutions & Deployment Support
Beyond individual products, Aumictech provides end-to-end solutions for manufacturing line deployment and test station setup. Our team can assist with system integration, configuration, and equipment selection tailored to your production requirements.

Trusted Industry Experience
With over a decade of experience, Aumictech is a recognized leader in RF and optical test equipment sales and services. All units are supported by our in-house calibration and repair facility based in Downingtown, PA, ensuring technical reliability and long-term value.

Customer Commitment
We’re committed to exceptional customer service, offering a 15-day return or replacement (ROR) policy for peace of mind. Our team is always available to assist with pre- and post-sale support.

Fast Shipping & Flexible Payments
We offer rapid global shipping through FedEx, UPS, and DHL, with most orders dispatched within 1–3 business days. Multiple secure payment options are available, including PayPal, ACH, wire transfers, and major credit cards.

You May Also Like

Can't Find The Right Product? Contact Us.