The California Instruments 5001IX is a versatile AC/DC power source and power analyzer designed for comprehensive testing and simulation of electrical power conditions. This instrument is engineered to meet the demands of product development, compliance testing, and quality control across various industries. Its capabilities include programmable voltage and frequency, arbitrary waveform generation, and integrated power analysis, making it a robust solution for simulating diverse global power scenarios and verifying product performance against international standards.
### Technical Specifications
**General**
* **Manufacturer:** California Instruments
* **Model:** 5001IX
* **Series:** iX Series II
* **Type:** Programmable AC/DC Power Source and Power Analyzer
* **Output Power:** 3000 VA to 15000 VA (configuration dependent). Specifically, 5 kVA models are available.
* **Phases:** Single-Phase or Three-Phase Configurable (with MODE-iX option for automatic switching)
* **Operation Modes:** AC, DC, and AC+DC Output Modes
* **Cooling:** Forced air cooling, side air intake, rear exhaust
* **Operating Humidity:** 0 to 95% RH, non-condensing
**Electrical Output**
* **AC Output Voltage Range:** 0 – 300V AC (low/high range: 0-150V/0-300V). Note: AC voltage in the 300V range derates from 300 Vrms max. at 500 Hz to 150 Vrms max. at 1000 Hz.
* **DC Output Voltage Range:** 0 – 400V DC
* **Frequency Range:** 16 Hz – 5000 Hz. Specifically, 16 Hz to 1000 Hz for certain configurations, and 16 Hz to 48 kHz measurement system bandwidth.
* **Maximum Current Per Phase:** AC (Low V range): Up to 110 Amps peak. AC (Low V range): 37A.
* **Crest Factor:** Up to 5:1
* **DC Offset Voltage:** Less than 20 mV with linear load.
* **Harmonic Distortion (Linear):** < 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load).
* **Isolation Voltage:** 300 Vrms output to chassis.**Power Analyzer Capabilities**
* **Measurements:** Standard measurements including harmonics. Built-in digital power analyzer. Harmonic analysis of Voltage and Current.
* **Harmonic Analysis:** Detailed amplitude and phase information on up to 50 harmonics of the fundamental voltage and current. Total harmonic distortion (THD) of voltage and current calculated from harmonic data.
* **Waveform Acquisition:** Real-time digitization of voltage and current waveforms using a 4K deep sample buffer. Captured waveforms can be displayed, printed, and saved.
* **Scope Capture Capability:** Yes**Arbitrary Waveform Generation**
* **Capability:** Arbitrary waveform generation.
* **User Defined Waveform Storage:** Four groups of 50 user-defined arbitrary waveforms of 1024 points for a total of 200 (One group can be active at a time).
* **Waveform Types:** Sine, Square, Clipped sine, User-defined.**Compliance Testing**
* **Standards Supported:** EN61000-3-2 and EN61000-3-3 compliant. Supports compliance testing for standards like MIL-STD-704, DO-160, IEC 61000. Compliance with IEC 61000-3-2 and IEC 61000-3-3. RTCA/DO-160D and EU- standards are supported with specific options. Programmable output impedance for IEC 725 reference impedance for flicker testing.**Interfaces**
* **Remote Control:** Standard IEEE-488 (GPIB) and RS232C interfaces. Optional LAN/USB.
* **Programming Protocol:** SCPI command protocol.
* **System Interface:** Inputs: Remote shutdown, External Sync, Clock/Lock (option). Outputs: Function Strobe, Clock/Lock (option).**Physical**
* **Dimensions:** Rack slide dimensions shown as 19.00 48.26 inches.
* **Storage:** Non-Volatile Memory for 16 instrument setups and 200 user-defined waveforms.### Why Choose Aumictech for California Instruments 5001IX?At Aumictech, we specialize in supplying high-end AC/DC power sources and analyzers. Whether you need precise simulation of global power conditions, robust compliance testing capabilities, or versatile arbitrary waveform generation, our team ensures the California Instruments 5001IX delivers maximum performance for your application.