The Corning SMF-LS Optical Bare Fiber 13 km CPC6 is a single-mode fiber engineered for long-distance telecommunications and high-bandwidth data transmission. The fiber delivers low attenuation across C and L bands with a CPC6 protective coating that enables reliable stripping and integration into diverse cable architectures—tight buffer, ribbon, loose tube, and slotted core designs. Operating from −60 °C to +85 °C with stable performance across temperature and humidity cycling, this fiber meets ITU-T G.652.B standards and supports modern DWDM systems.
– Technical Specifications
Fiber Geometry
• Core diameter: 8.3 µm
• Cladding diameter: 125.0 ± 2.0 µm
• Core-clad concentricity: ≤ 0.3 µm (ITU-T G.652.B-compliant)
• Cladding non-circularity: ≤ 0.7%
• Core non-circularity: ≤ 5%
Coating Geometry
• Coating diameter: 245 µm nominal (245 ± 10 µm)
• Coating-cladding concentricity: ≤ 0.3 µm
Optical Performance
• Numerical aperture: 0.13
• Operating wavelengths: 1310 nm (primary), 1550 nm (secondary)
• Cut-off wavelength: 1220–1300 nm
• Zero dispersion wavelength (λ₀): 1297–1316 nm
• Zero dispersion slope: ≤ 0.101 ps/(nm²•km)
• Attenuation at 1310 nm: ≤ 0.35 dB/km
• Attenuation at 1550 nm: ≤ 0.25 dB/km (typical: 0.19 dB/km)
• PMD link value: ≤ 0.5 ps/√km
• Point discontinuity: ≤ 0.10 dB at 1310 nm or 1550 nm
Environmental Stability
• Temperature range: −60 °C to +85 °C
• Temperature-induced attenuation change: ≤ 0.05 dB/km
• Humidity cycling attenuation: ≤ 0.05 dB/km (−10 °C to +85 °C, 98% RH)
Mechanical
• Proof test: ≥ 100 kpsi (0.7 GN/m²)
– Key Features
• ITU-T G.652.B compliance ensures interoperability with legacy and modern infrastructure
• Low attenuation and controlled dispersion support 13 km links with minimal signal degradation
• CPC6 coating provides mechanical protection and simplified cable processing
• Tight core-clad and coating concentricity tolerances (≤ 0.3 µm) minimize mode-field diameter variation
– Typical Applications
• Long-haul and metro DWDM systems
• Campus and regional backbone networks
• Cable television and broadband distribution
• Direct-burial and armored cable assemblies
– Compatibility & Integration
This fiber integrates into tight buffer, ribbon, loose tube, and slotted core cable designs. The standard 245 µm coating diameter and 125 µm cladding conform to industry connector and fusion splicer specifications. Performance is verified across the extended temperature range (−60 °C to +85 °C) and under thermal cycling stress.