The EDC MV-106 is a precision DC voltage standard designed for applications requiring highly stable and accurate voltage outputs. This instrument is suitable for use in standards laboratories, automated calibration systems, production line testing, and as a reference for computer systems. It utilizes a chopper-stabilized amplifier for maintaining output stability and a temperature-compensated, aged zener diode as its voltage reference. The device offers multiple voltage ranges and high resolution, enabling precise calibration of various measuring instruments.
### Technical Specifications
**Electrical Characteristics:**
* **Output Voltage Ranges:**
* 10 mV DC (±11.11110 mV DC)
* 100 mV DC (±111.1110 mV DC)
* 10 V DC (±11.11110 V DC)
* **Resolution:**
* 10 mV range: 0.01 µV
* 100 mV range: 0.1 µV
* 10 V range: 10 µV
* **Output Current:** 50 mA into a load resistance (RL) > 100 kΩ
* **Stability (1 year):** ±(0.0025% of range + 2 µV)
* 8-hour period: ±(0.001% of range + 2 µV)
* **Output Accuracy:** ±(0.003% of setting + 0.0005% of range + 2 µV)
* **Ripple and Noise:**
* 10 V Range: 50 µV
* 100 mV Range: 1 µV
* 10 mV Range: 0.1 µV
* **Temperature Coefficient (Tempco):** ±0.001%/°C (Declared as 10 ppm/°C in some sources)
* **Warm-up Time:** 30 seconds minimum, 60 minutes maximum
* **Calibration Temperature:** 23 °C ±1 °C
* **Voltage Reference:** Temperature-compensated, aged zener diode
* **Stabilization:** Chopper-stabilized amplifier
**Electrical Protection:**
* **Circuit Condition Indicator:** Front panel indicator for short circuit, overload, over-voltage condition, low line voltage, or malfunction
* **Protection:** Short circuit and overload protection with automatic recovery
* **Short Circuit Tolerance:** Can drive a short circuit indefinitely without damage and recovers to rated specifications in less than 2 minutes
**Interfaces:**
* **Output Terminals:** 4 terminals provided for output and sense (local and remote sensing capable)
* Red terminals indicate polarity with respect to the black (common) terminals
* Includes shorting bars for local sensing
* **Power Input:** Standard three-prong polarized plug; internal multitap transformer selectable for 115VAC or 230VAC via slide switch
**Physical Characteristics:**
* **Dimensions:** 133 mm (Height) x 432 mm (Width) x 277 mm (Depth)
**Compatibility:**
* **Applications:**
* Calibration of digital voltmeters
* Calibration of analog meters
* Semiconductor analyzing systems
* Analog references for computers
* Analog-to-digital converters
* Telemetry and data acquisition systems
* Standards laboratories
* Automated calibration systems
* Production line testing
### Why Choose Aumictech for EDC MV-106?
At Aumictech, we specialize in supplying high-end electronic standards and calibration equipment. Whether you need precise DC voltage generation for critical test procedures, reliable calibration of your multimeters, or stable voltage references for complex systems, our team ensures the EDC MV-106 delivers maximum performance for your application.




















Reviews
There are no reviews yet.