The Elgar 1203SL-9023 is a three-phase AC power source designed for precision testing and simulation of AC power conditions. It offers versatile voltage and frequency outputs for evaluating linear loads across their operational parameters. This unit is engineered with solid-state technology for reliable performance in demanding applications such as electronics manufacturing, research and development, and compliance testing.
### Technical Specifications
**Output Characteristics:**
* **Output Power:** 400 VA per phase, 1200 VA total.
* **Output Voltage Ranges:** 0-65 VAC RMS, 0-130 VAC RMS, 0-260 VAC RMS, selectable via internal transformer. The rated VA is available from 55-65 VAC on the low range, 110-130 VAC on the mid range, and 220-260 VAC on the high range with a power factor from unity to +/- 0.7.
* **Total Harmonic Distortion (THD):** Typically better than 0.4%. Maximum THD is 0.4% from 200 Hz to 1 kHz, and 0.6% from 45 Hz to 5 kHz.
* **Output Frequency:** 45 Hz to 5000 Hz (5 kHz). Programmable with auto-ranging capabilities.
* **Load Regulation:** +/-1% from 45 Hz to 5 kHz with a unity power factor. For fixed frequency systems, load regulation is +/-0.25% between 45 Hz and 1 kHz.
* **Line Regulation:** +/-0.25% of full scale output voltage at rated VA for a 10% input line change.
* **Programmable Current Limit:** 5% – 100% of range, with 0.01 A resolution, programmable simultaneously for all phases.
**Performance and Features:**
* **Response Time:** Less than 50 microseconds.
* **AC Noise Level:** 70 dB below full output.
* **Gain Stability:** +/-0.25% for 24 hours at constant line, load, and temperature after warm-up.
* **Programmable Amplitude Execution:** Options include Random, Zero-Crossing, and Peak execution.
* **Line Cycle Drop-Out:** Programmable for 1 to 9 line cycles.
* **Overload and Temperature Protection:** Included for protection.
* **Fault Shutdown:** Initiated for over/under voltage, overload, and over current conditions.
* **Series and Paralleling Capabilities:** Supported for expanded output configurations.
* **Low Effective Output Impedance:** A characteristic of the design.
* **Continuous Duty:** Capable of continuous duty at 150% of rated capacity into a linear resistive load.
**Programming and Control:**
* **Programmability:** Manual or IEEE-488 (GPIB) programmable using Elgar’s Plug-in Programmers (PIP).
* **Status Reporting:** 10 functions available via GPIB, plus visual indication.
* **Self-Test:** Continuous self-testing with SRQ (Service Request) capability.
* **Confidence Test:** Supported with CIIL (Common Industrial Interface Language).
* **Disconnect Relay Control:** Included.
* **MATE Compatible:** Optional embedded TMA (Test Module Assembly) function available.
### Electrical Specifications
**Input:**
* **Input Voltage Options:** 115 VAC, 208 VAC, or 230 VAC, single phase, +/-10%. Specific configurations such as 1203SL-14T (115VAC), 1203SL-24T (230 VAC), and 1203SL-34T (208 VAC) are available.
* **Input Frequency:** 47 Hz to 63 Hz continuous, with 45-70 Hz short-term transients.
* **Input Power:** Maximum 3400 Watts.
* **Input Volt-Amperes:** Maximum 5100 VA.
### Interfaces
* **IEEE-488 (GPIB):** Supported for remote programming and control.
### Physical Specifications
* **Dimensions:** 8.25 inches (height) x 19.0 inches (width) x 21.0 inches (depth) from the front panel mounting surface. The unit has a 9-inch panel height.
* **Net Weight:** 175 lbs.
* **Shipping Weight:** 225 lbs (typical).
* **Rack Mountable:** Designed for standard 19-inch rack mounting.
### Environmental Specifications
* **Operating Temperature Range:** 0 degrees C to 50 degrees C (32 degrees F to 122 degrees F). Some sources indicate -20° to +50°C.
* **Humidity Range:** Up to 95%, non-condensing.
### Compatibility
* **Plug-In Programmers (PIP):** Requires a PIP for full IEEE-488 programmability. Compatible PIPs include models 9012A, 9023, and 704, provided they also have the “Test” option. The 9023 PIP is specifically mentioned as being bundled with some 1203SL configurations.
* **Plug-In Oscillator Modules:** Such as the Elgar 403SD series, are used for frequency control and are often sold with the mainframe. The 9023-3 is a 3-phase plug-in oscillator for 45 Hz to 5 kHz.
* **Standards Compliance:** The Elgar 1203SL is relevant for testing related to standards such as ANSI C62.41 and IEEE C62.41.
Why Choose Aumictech for the Elgar 1203SL-9023?
At Aumictech, we specialize in supplying high-end AC power source equipment. Whether you need precise voltage and frequency simulation, reliable performance for manufacturing test, or robust solutions for R&D and compliance testing, our team ensures the Elgar 1203SL-9023 delivers maximum performance for your application.


























Reviews
There are no reviews yet.