The Elgar AT8000A-160V MOD is a modular, high-density programmable DC power system designed for automated test equipment (ATE) applications in production testing, incoming inspection, repair facilities, and quality control environments. This system is capable of accepting both power supply and electronic load modules within a single 5-1/4″ mainframe, allowing for up to six independent channels in a 19″ rackmount chassis. The AT8000A system can be expanded to accommodate up to 16 channels across master and expansion chassis configurations, all controllable via a single IEEE-488 GPIB address. It offers local control through a front-panel keyboard and remote control via GPIB. The system’s modular design allows for flexible configuration, integrating linear DC power and electronic load modules to simulate various operating conditions and test subassemblies or PCBs.
### Technical Specifications
* **System Configuration:**
* Modular design accepting both DC power supply and electronic load modules.
* Up to six independent channels per 5-1/4″ high-density mainframe.
* Expandable to 16 channels using master/expansion chassis configurations.
* Each mainframe is 19″ wide and rackmountable.
* Total system power capability up to 19.2 kW in a multi-chassis setup.
* **Power Module Specifications:**
* Individual power modules deliver 200W.
* Paralleling power modules within a single chassis can deliver up to 1200W.
* Highly efficient linear design ensures fast response time and low ripple.
* Specific voltage modules are available, with mentions of up to 160V for the AT8000A-160V MOD. Other sources mention voltages up to 320V and modules up to 80 VDC.
* **Maximum Resolution:**
* 10 mV and 10 mA for modules < 100V.
* 10 mV and 10 mA for modules 100V or higher.
* 1.76 mV for 7 VDC modules.
* **Maximum Ripple and Noise (Voltage Mode):**
* 1.5 millivolt RMS or 0.01% of rated output voltage, whichever is greater, from 20 Hz to 100 kHz.
* For master-slave configurations: 5 millivolts RMS or 0.01% of rated output voltage, whichever is greater, from 20 Hz to 200 MHz.
* 15 millivolts peak-to-peak or 0.05% of rated output voltage, whichever is greater, from 20 Hz to 200 MHz.
* **Electronic Load Module Specifications:**
* Individual load modules deliver 300W.
* Paralleling load modules can deliver up to 1800W per chassis.
* Supports four primary operational modes: Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR), and Transient Operation.
* Programmable slew rates to simulate real-world dynamic load conditions.
* **Control and Interfaces:**
* Local control via front-panel keyboard and display.
* Remote control via IEEE-488 GPIB (one selectable bus address).
* Supports programming languages: ABLE (Atlas Based Language Extension) and CIIL (Control Interface Intermediate Language) for MATE applications.
* Built-in test option for readback capability of voltage and current readings.
* Front panel features a 16-pad multi-level keyboard with increment/decrement keys, LEDs, and displays for programming and status indication.
* **Protection and Features:**
* Overcurrent sensing and overvoltage protection with SCR crowbar shutdown are standard.
* Load isolation (confidence) relays are standard.
* Optional polarity switching relays.
* Integrated output relay and independent SCR crowbar for rapid grounding (discharge).
* Remote Sense terminals for precise voltage regulation at the load.
* Auxiliary Drive Modules (ADMs) can extend the power range of a channel up to 10 kW or more by integrating external bulk power supplies.### Electrical* **Input Voltage:** Not explicitly detailed for the AT8000A-160V MOD, but the system is designed for standard AC power input suitable for test environments.
* **Output Voltage:** Modular, with specific modules providing voltage ranges up to 160V for the AT8000A-160V MOD. Other modules in the AT8000A series offer voltages up to 320V.
* **Output Current:** Varies by module configuration; electronic load modules are rated at 300W, and power modules at 200W, with paralleling capabilities to increase total output.
* **Power:** Up to 1200W per chassis via paralleled power modules; up to 19.2 kW in a multi-chassis system.### Interfaces* **Primary Interface:** IEEE-488 GPIB for remote programming and control.
* **Front Panel:** Keyboard and LED/display interface for local operation.
* **Module Interconnects:** Interface cables for connecting master and slave chassis are available.### Physical* **Chassis Size:** 5-1/4" high-density mainframe, 19" wide rackmount chassis.
* **Module Form Factor:** Designed to fit within the AT8000A mainframe.### Compatibility* **ATE Systems:** Designed for compatibility with Automated Test Equipment (ATE) environments.
* **Programming Languages:** Supports ABLE and CIIL for MATE applications, facilitating integration with established ATE programming standards.
* **Module Expansion:** Supports master/expansion chassis configurations for system scalability.### Why Choose Aumictech for the Elgar AT8000A-160V MOD?
At Aumictech, we specialize in supplying high-performance ATE equipment. Whether you need a configurable, modular DC power solution, robust electronic load simulation, or precise power source testing, our team ensures the Elgar AT8000A-160V MOD delivers maximum performance and reliability for your demanding engineering and procurement requirements.