The Fluke 8024B is a portable digital multimeter engineered for electronics troubleshooting and field measurements across DC/AC voltage, current, resistance, and specialized signal analysis. Its dual-slope integration architecture delivers noise-free measurements with a 3½-digit LCD display (1,999 count maximum) featuring autozero and autopolarity. The instrument captures transient signals via peak-hold, detects logic levels up to 250 V AC/DC RMS, and tests continuity with visual and audible indication. Diode testing and temperature measurement (K-type thermocouple, not included) extend diagnostic capability. A single 9 V battery powers the meter for approximately 100 hours with alkaline chemistry, with low-battery indication displayed as “BT” at ≈20% capacity. Overload protection on all ranges and glass fuse input protection ensure safe operation. The compact design—18.0 cm × 8.6 cm × 4.5 cm, 0.48 kg—fits standard tool kits. Safety-featured test leads with finger guards and shrouded connectors meet CAT II measurement category requirements.
## Technical Specifications
• **Display:** 3½-digit LCD, 1,999 count maximum; autozero and autopolarity
• **DC Voltage:** 200 mV to 1,000 V
• **AC Voltage:** 200 mV to 750 V (average sensing, RMS-indicating)
• **DC Current:** 2 mA to 2,000 mA
• **AC Current:** 2 mA to 2,000 mA
• **Resistance:** 200 Ω to 20 MΩ
• **Conductance:** Up to 10,000 MΩ
• **Peak-Hold:** Transient AC/DC signal capture
• **Level Detector:** Logic levels and active signals to 250 V AC/DC RMS
• **Common Mode Voltage:** Maximum 500 V DC or RMS
• **Measurement Category:** CAT II
• **Input Protection:** Glass fuse and clamping circuit
• **Calibration Stability:** 2-year cycle
## Key Features
• Dual-slope integration for noise-free measurements
• Diode test and continuity testing with audible feedback
• Temperature measurement capability (thermocouple not included)
• Effective overload protection across all ranges
• High-contrast LCD readable at distance
• Low-battery indicator
## Power & Operating Conditions
• **Power Source:** Single 9 V battery (NEDA 1604)
• **Battery Life:** Alkaline 100 hours typical; zinc carbon 50 hours typical
• **Operating Temperature:** 0 °C to 50 °C
• **Storage Temperature:** -35 °C to +60 °C
• **Line Operation:** Compatible with Model A81 Battery Eliminator
## Typical Applications
Electronics service and repair, HVAC troubleshooting, automotive diagnostics, and preventive maintenance where transient signal capture and logic-level detection are required.