The HP/Agilent 4192A LF Impedance Analyzer measures impedance and admittance across the 5 Hz to 13 MHz frequency range, delivering 4½-digit resolution for characterizing components, filters, and materials in development, quality control, and production settings. This analyzer tests both floating and grounded devices with direct readout of 13 impedance parameters—|Z|, |Y|, R, X, L, C, Q, D, and associated phase and loss metrics—plus gain-phase measurements including amplitude, phase, and group delay.
## Technical Specifications
**Frequency Range**
• 5 Hz to 13 MHz with 1 mHz maximum resolution
• Frequency step size: 0.001 Hz (5 Hz to 10 kHz), 0.01 Hz (10 kHz to 100 kHz), 0.1 Hz (100 kHz to 1 MHz), 1 Hz (1 MHz to 13 MHz)
**Measurement Parameters**
• Impedance: |Z|, |Y|, Theta, R, X, G, B, L, C, D, Q, Delta, Delta%
• Gain-Phase: Amplitude, Phase, Group Delay
• Display: 4½ digits with series and parallel equivalent circuit modes
**Test Signal**
• Level range: 5 mV to 1.1 Vrms
• Accuracy: ±((5 + 10/f)% of setting + 2 mV) for 5 Hz to 1 MHz; ±((4 + 15 × F)% of setting + 2 mV) for 1 MHz to 13 MHz
**Internal DC Bias**
• ±35 V with 10 mV increments
• Setting accuracy: 0.5% of setting + 5 mV
**Measurement Range**
• Impedance: 0.1 mΩ to 1 MΩ
• Admittance: 1 nS to 10 S
• Accuracy: |Z|/R/X ±0.15%, |Y|/G/B ±0.15%, Theta ±0.08°, L ±0.27%, C ±0.15%
## Key Features
• Built-in frequency synthesizer with linear or logarithmic sweep modes
• Automatic ZERO adjustment for test fixture offset normalization
• Spot and swept control via front panel or HP-IB
• 425.5 mm W × 235 mm H × 615 mm D; approximately 19 kg
## Typical Applications
• Telecommunication filter characterization
• Audio/video circuit analysis
• Material property evaluation
• Component impedance profiling across low-frequency spectrum
## Compatibility & Integration
• HP-IB (IEEE-488) interface for remote operation and data acquisition



























Reviews