The HP/Agilent 54201A is a two-channel digital storage oscilloscope delivering simultaneous real-time and repetitive waveform acquisition for electronic testing and measurement. It combines a 300 MHz repetitive bandwidth with 50 MHz single-shot bandwidth and a maximum sample rate of 200 megasamples/second, enabling capture of both fast transients and repetitive signals across diverse applications.
– Technical Specifications
Acquisition & Digitization
• Two-channel simultaneous acquisition
• Real-time and random repetitive digitizing modes
• 200 megasamples/second maximum sample rate
• 1001-sample record length (1000 intervals)
• 6-bit vertical resolution; effective 7-bit with filtering and averaging
• Four non-volatile waveform memories
Bandwidth & Transition Time
• Repetitive bandwidth: DC to 300 MHz
• Single-shot bandwidth: DC to 50 MHz
• Repetitive-mode transition time (10%-90%): 1.2 ns
• Real-time transition time (10%-90%): 7 ns
Timebase Accuracy
• Real-time mode: ±2 ns or ±0.2% of time range (whichever greater)
• Repetitive mode: ±200 ps or ±0.2% of time range (whichever greater)
• Time-interval accuracy: ±200 ps
Vertical Input
• Input impedance: 1 MΩ shunted by ~10 pF, or 50 Ω DC
• Probe attenuation: 1:1, 2:1, 5:1, 10:1, 20:1, 50:1, 100:1
• AC/DC coupling
• Channel isolation: 50 dB (DC to 50 MHz); 40 dB (50 MHz to 300 MHz)
• Maximum safe input: ±40 V (DC + peak AC) at 1 MΩ; 5 Vrms or ±40 V at 50 Ω
Trigger
• Sources: Channel 1, Channel 2, External
• Edge-selectable trigger (positive or negative slope)
• Sensitivity: 1/8 full scale or 100 mVp-p to 1 Vp-p depending on coupling
• Level range: ±1.5× full scale (channels); ±2 V (external)
• Level accuracy: ±3% ±5 mV to ±3% ±100 mV (depending on range)
Horizontal Timebase
• Real-time: 50 ns to 10 s full-scale
• Repetitive: 10 ns to 20 µs full-scale
• Pre-trigger: up to 10 µs (real-time); up to 2 screen diameters (repetitive)
• Post-trigger: at least 200 screen diameters
– Key Features
• Parametric waveform measurements and digitized data output
• Flexible trigger controls with sub-nanosecond timing accuracy
• Dual sampling modes optimize capture of transient and repetitive signals
• Multiple probe attenuation factors for wide dynamic range testing
– Typical Applications
• Digital and analog circuit characterization
• High-speed signal acquisition and waveform analysis
• Device timing verification and transient measurement
• General electronic testing and troubleshooting
– Compatibility & Integration
Part of the 54201D product family; operates as a standalone instrument with resident measurement capabilities and waveform storage for post-acquisition analysis.



























Reviews