The HP/Agilent 6683A is a 5000 W DC power supply engineered for high-current, precision testing and system integration. Delivering 0–32 V and 0–160 A with programming accuracy of 0.04% + 32 mV (voltage) and 0.1% + 85 mA (current), it meets demanding requirements in automated test environments. Output ripple and noise measure 1.0 mV RMS and 10 mV peak-to-peak across 20 Hz to 20 MHz. The unit supports analog voltage and current modulation via 0 to –5 V and 0 to +5 V input signals respectively, with full-load programming response of 9 ms. Protection includes programmable over-voltage and over-current limits, over-temperature shutdown, and discrete fault indicator/remote inhibit capability.
– Technical Specifications
• Output: 0–32 V, 0–160 A, 5000 W (5120 W maximum)
• Programming Accuracy (25 ± 5°C): Voltage 0.04% + 32 mV; Current 0.1% + 85 mA
• Readback Accuracy: Voltage 0.05% + 7.5 mV
• Ripple & Noise (20 Hz–20 MHz): 1.0 mV RMS, 10 mV peak-to-peak
• Response Time: 9 ms (10–90% full-load programming, resistive load)
• Analog Modulation: Voltage input 0 to –5 V; Current input 0 to +5 V; Input impedance ≥30 kΩ
• AC Input: 180–235 Vac (3-phase, 47–63 Hz, max 27.7 A RMS) or 360–440 Vac (3-phase, 47–63 Hz, max 14.3 A RMS); 5% voltage derating at 50 Hz and below 200 Vac
• Input Power: Maximum 7350 VA / 6000 W; No-load 160 W
• Dimensions: 425.5 mm W × 221.5 mm H × 674.7 mm D
• Weight: 51.3 kg net (63.6 kg shipping)
– Key Features
• Programmable over-voltage and over-current protection
• Over-temperature protection with discrete fault indicator/remote inhibit
• Low output ripple and noise for sensitive loads
• Selectable load compensation for inductive circuits
• Fan-speed control for acoustic noise reduction
• Installation Category III rated for industrial environments; 95% maximum relative humidity; operation to 2000 m altitude
– Typical Applications
High-current automated test systems, power device characterization, burn-in testing, and integration into multi-unit test benches requiring precision voltage and current sourcing.
– Compatibility & Integration
• GPIB interface with IEEE-488.2 and SCPI command set support
• VXI plug&play drivers
• Serial link capability for daisy-chaining up to 16 units to a single GPIB address
• Analog programming for voltage and current modulation

























Reviews