Keysight / Agilent / HP 3396 Series III Integrator

SKU: 3396 Series IIICategories: Data Acquisition Systems (DAQ)
30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • 100% Verified & Tested Equipment
  • Rental Units Available
Request Repair
Product Starting From:

$850.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 3396 Series III
Equipment info

The Keysight/Agilent/HP 3396 Series III Integrator is a laboratory data handling and instrument control system for Gas Chromatography (GC) and High-Performance Liquid Chromatography (HPLC) applications. It provides automated data analysis, peak integration, and calibration management with built-in BASIC language for custom programming. The unit accepts analog voltage inputs from non-INET instruments and digital data from INET-compatible chromatography systems, processing signals at 20 slices per second (0.05 second slice width). Memory expansion capabilities and sequence chaining enable multi-method workflows across Agilent and third-party instruments.

## Technical Specifications

• **Memory:** 256 kbytes internal storage; two expansion card slots; power-failure protected
• **Data Sampling:** 0.05 second slice width (20 slices/second) for analog input conversion
• **Connectivity:** RS-232 communications port; supports INET instrument set point storage
• **Power Requirements:** 115 V or 230 V ac (±15% to −22%); 48–66 Hz; 50 VA maximum
• **Operating Environment:** 5°C to 40°C; up to 2000 m altitude; 10–90% relative humidity (non-condensing); corrosive-chemical-free atmosphere; indoor use only
• **Physical Footprint:** 46 cm width × 46 cm depth; requires 46 cm clearance above unit
• **Safety Classification:** IEC Class 1

## Key Features

• Automated baseline drawing and post-run reintegration
• Point-Point, Linear, and Non-Linear calibration curve analysis
• Peak recognition and multi-level calibration support
• Automatic file naming and sequence chaining with NEXT SEQUENCE function
• Chromatogram replotting and baseline redrawing capabilities
• Compatible with HP 6890 GC programming; leverages instrument set point storage for INET devices
• Supports non-INET samplers and Remote Start/Stop (RSS) configurations

## Typical Applications

• GC and HPLC data acquisition and processing
• Multi-sample batch analysis with automated reporting
• Custom method development via embedded BASIC
• Reintegration of archived chromatograms with alternate parameters

## Compatibility & Integration

Operates with Agilent instruments (e.g., HP 5890 GC, HP 6890 GC) and non-Agilent chromatography systems. Accepts analog voltage input and digital data streams from INET instruments. Data file management supports sequence storage and post-run method assignment across chained runs.

MPN

3396 Series III

Reviews

There are no reviews yet.

Be the first to review “Keysight / Agilent / HP 3396 Series III Integrator”

Your email address will not be published. Required fields are marked *

Product Condition & Availability
Keysight / Agilent / HP 3396 Series III Integrator is in excellent working condition and has been thoroughly tested for performance and reliability. We offer both new and professionally refurbished options, depending on availability and customer preference.

 

Integrated Solutions & Deployment Support
Beyond individual products, Aumictech provides end-to-end solutions for manufacturing line deployment and test station setup. Our team can assist with system integration, configuration, and equipment selection tailored to your production requirements.

Trusted Industry Experience
With over a decade of experience, Aumictech is a recognized leader in RF and optical test equipment sales and services. All units are supported by our in-house calibration and repair facility based in Downingtown, PA, ensuring technical reliability and long-term value.

Customer Commitment
We’re committed to exceptional customer service, offering a 15-day return or replacement (ROR) policy for peace of mind. Our team is always available to assist with pre- and post-sale support.

Fast Shipping & Flexible Payments
We offer rapid global shipping through FedEx, UPS, and DHL, with most orders dispatched within 1–3 business days. Multiple secure payment options are available, including PayPal, ACH, wire transfers, and major credit cards.

You May Also Like

Can't Find The Right Product? Contact Us.