The Keysight/Agilent/HP 3577A Network Analyzer paired with the 35677B S-Parameter Test Set delivers precision impedance and S-parameter measurements from 5 Hz to 200 MHz. This dual-unit system excels in design and production environments, characterizing two-port devices with high speed and accuracy. The 3577A employs individual precision analog receivers for each input, eliminating signal multiplexing to preserve measurement integrity. Both units are fully programmable via HP-IB (IEEE 488), enabling automated test sequences and seamless integration into larger measurement systems.
## Technical Specifications
**Keysight/Agilent/HP 3577A Network Analyzer:**
• Frequency Range: 5 Hz to 200 MHz
• Frequency Resolution: 0.001 Hz
• Output Power: 0 dBm
• Dynamic Range: Greater than 130 dB (with noise reduction)
• Receiver Input Impedances: 50 Ω or 1 MΩ (selectable)
• Measurement Resolution: 0.001 dB, 0.005 degrees, 1 ps
• Display Modes: Magnitude, phase, polar, real, imaginary, group delay
• Error Correction: Three-term vector error correction and normalization
• Noise Reduction: Vector noise averaging with selectable resolution bandwidth filters
• External Reference: 10 MHz input/output (BNC, rear panel)
• External Trigger: TTL or contact closure (BNC, rear panel)
• Storage: Non-volatile memory for five front-panel setups
• Power: 115 V or 230 V, 47–440 Hz, 450 VA maximum
• Dimensions: 222 mm H × 426 mm W × 578 mm D
• Weight: 31 kg (net)
**Keysight/Agilent/HP 35677B S-Parameter Test Set:**
• System Compatibility: HP 3577A Network Analyzer
• Frequency Range: 100 kHz to 200 MHz
• Test Port Impedance: 75 Ω
• Directivity: >40 dB
• Frequency Response (S21, S12): ±1 dB, ±5 degrees
## Key Features
• Vector error correction and normalization minimize systematic errors
• Binary or ASCII data transfer via HP-IB for fast automated workflows
• HP-GL graphics plotter control for direct output integration
• Dual-receiver architecture eliminates multiplexing losses
• Selectable impedance matching (50 Ω or high-impedance modes)
• Group delay, insertion loss, return loss, and reflection coefficient measurement
## Typical Applications
Filter and amplifier characterization, transmission line analysis, device impedance profiling, gain compression testing, and phase distortion measurement across baseband to VHF frequencies.
## Compatibility & Integration
HP-IB programming enables remote control and data acquisition. External 10 MHz reference input supports phase-locked system operation. TTL trigger input synchronizes measurements with external test sequences.