The Keysight/Agilent/HP E1432A is a C-size, single-slot VXI measurement module delivering 16-channel data acquisition and onboard digital signal processing in a single card. It accommodates up to four 4-channel input assemblies, each digitizing at 51.2 kSa/s with 16-bit resolution. A 33 MHz Motorola 96002 DSP processor handles real-time signal processing, while up to 32 MB of DRAM and dual 128K word static RAM banks support high-speed computation and data storage. The module conforms to VXI revision 1.4 standards and integrates transducer signal conditioning, anti-alias filtering, and measurement computation. With Option 1D4, a 16-bit arbitrary source adds sine, random, and arbitrary waveform generation capability with output amplitude of 10 Vp nominal and 50Ω output impedance.
## Technical Specifications
• **Module Type:** C-size, single-slot VXI measurement module
• **VXI Conformance:** VXI revision 1.4
• **Channels:** Configurable 4 to 16 channels (four 4-channel input assemblies)
• **Sample Rate:** 51.2 kSa/s per channel maximum
• **ADC Resolution:** 16 bits
• **DSP Processor:** 33 MHz Motorola 96002
• **Memory:** Up to 32 MB DRAM; 2 banks of 128K word static RAM
• **FIFO Depth:** 2 MSa/number of active channels (4 MB DRAM standard); 16 MSa/number of active channels (32 MB DRAM with Option ANC)
• **Data Transfer Rates:** Local bus 15.7 MB/s; VXI path 15 Mbytes/sec (7.5 Msamples/sec); VME bus 6.9 MB/s (16-bit integer) or 27.6 MB/s (64-bit floating point)
• **Synchronization:** 2 or 4 TTL TRG_ lines for multi-module sync
## Key Features
• Integrated signal conditioning and anti-alias filtering
• Onboard DSP for high-speed measurement computation
• Optional 16-bit arbitrary source (Option 1D4) with sine, random, and arbitrary waveforms
• Reconstruction filter bandwidth (Arb modes): 0 to 6.4 kHz
• A24 address and D32 data transfer capability
## Electrical Specifications
• **Source Output (Option 1D4):** 10 Vp nominal amplitude; 50Ω output impedance
• **Source Sample Rate:** Matches input channel sample rate; cannot be 40.000 kHz when active
## Typical Applications
Multi-channel vibration monitoring, structural health assessment, acoustic measurement, transducer-based condition monitoring, and integrated data acquisition with real-time DSP processing.