The Mitsubishi FR-S5NFSA-0.75K is a Class-A EMC filter designed to suppress electromagnetic interference generated by variable frequency drives on the mains supply. It reduces high-frequency disturbances across the 150 kHz to 30 MHz band, ensuring compliance with EMC regulations and preventing conducted emissions that could affect other equipment. This single-phase filter is rated for 0.75 kW at 200–240 V AC (±10%, −15%) and integrates directly into the input mains of compatible Mitsubishi FR-S500, FR-E700, and FR-D700 series inverters.
– Technical Specifications
Electrical Ratings
• Supply voltage: 200–240 V AC (±10%, −15%)
• Single-phase (1P)
• Rated power: 0.75 kW
• Rated current: 14 A at 100% load
• Leakage current: 4.5 mA at 50 Hz and 500 Hz
• Overload capacity: 150% for 1 minute; 200% for 1 second
• Dielectric strength: 2000 V AC for 1 minute; 2400 V AC for 5 seconds
• Transient surge withstand: 5000 V peak (1.2 µs rise, 50 µs duration, 5 pulses)
Performance & Environmental
• Disturbance frequency range: 150 kHz–30 MHz
• Power dissipation: 8.55 W
• Ambient operating temperature: −10 to +50 °C
• Storage temperature: −20 to +65 °C
• Relative humidity: ≤90% RH (non-condensing)
Physical
• Width: 70 mm
• Weight: 0.8 kg
– Key Features
• Class-A EMC Directive compliance for industrial applications
• Mains conducted emissions performance: Curve A (industrial, 5 m output cable); Curve B (residential, 1 m output cable at 14.5 kHz)
• L1, N, PE input terminals with standard inverter output connections
• Low leakage current design (4.5 mA across 50 Hz and 500 Hz)
• Compact footprint enabling side-by-side or bookshelf mounting alongside inverter
– Compatibility & Integration
Direct compatibility with Mitsubishi FR-S500, FR-E700, and FR-D700 series inverters, including FREQROL FR-E710W-0.1K to FR-E710W-0.4K and FR-S520S EC/ECR models. Mount on cabinet back panel with electrical bonding to earth ground for optimal filter performance.

















Reviews