Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST Calibration Available on demand.

Service Support

Service plans available for the products’ durability

FAST REPAIRS

Overnight repairs available for selected products

Software Updates 

Staying up-to-date with lastest software updates.

Lifetime Support by Aumictech
Free OEM-grade Calibration
Fastest turnaround times

National Instruments USB-6229

SKU: USB-6229Categories: Data Acquisition Systems (DAQ)
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • 100% Verified & Tested Equipment
  • Rental Units Available

The National Instruments USB-6229 is a high-performance M Series multifunction data acquisition (DAQ) module designed for USB connectivity. It features 16 analog inputs, 4 analog outputs, 24 digital I/O lines, and advanced timing, triggering, and synchronization capabilities. Ideal for a wide range of applications including data logging, automated testing, and process control, the USB-6229 delivers exceptional accuracy and speed.

Request Repair
Product Starting From:

$0.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote USB-6229
Equipment info

The National Instruments USB-6229 is a high-performance M Series multifunction data acquisition module delivering 16-bit analog input and output, digital I/O, and counter/timer functionality over USB 2.0 Hi-Speed connectivity. The device acquires up to 250 kS/s per channel across 16 differential or 32 single-ended analog inputs with input ranges of ±0.2 V, ±1 V, ±5 V, and ±10 V. Four analog output channels provide ±10 V signals at update rates up to 833 kS/s on a single channel, scaling to 625 kS/s when all four channels are active. Up to 48 digital I/O lines support TTL/CMOS logic, with 32 lines capable of hardware-timed operation at 1 MHz. Two 32-bit counters/timers operate from an 80 MHz base clock, complemented by one frequency generator channel with 10 MHz and 100 kHz base clocks and 50 ppm accuracy.

– Technical Specifications

Analog Input
• 16 differential or 32 single-ended channels
• 16-bit ADC resolution with no missing codes guaranteed
• 250 kS/s maximum sample rate per channel
• ±0.2 V, ±1 V, ±5 V, ±10 V input ranges
• ±11 V maximum working voltage (signal + common mode)
• 700 kHz small signal bandwidth (−3 dB)
• 92 dB CMRR (DC to 60 Hz)
• ±100 pA input bias current
• 4,095-sample FIFO and scan list memory
• 50 ns timing resolution; 50 ppm timing accuracy
• 3,100 µV absolute accuracy on 10 V range (example)
• ±20 mA maximum input current during overvoltage protection

Analog Output
• 4 channels, 16-bit DAC resolution
• ±10 V output range
• Update rates: 833 kS/s (1 ch), 740 kS/s (2 ch), 666 kS/s (3 ch), 625 kS/s (4 ch)
• 0.2 Ω effective output resistance
• ±5 mA output current drive
• ±25 V overdrive protection
• 8,191-sample shared output FIFO
• 16-bit guaranteed monotonicity
• +1 LSB DNL

Digital I/O
• Up to 48 lines (TTL/CMOS)
• 32 lines hardware-timed at up to 1 MHz

Counters & Timers
• Two 32-bit counters/timers at 80 MHz base clock

Frequency Generator
• One channel; 10 MHz and 100 kHz base clocks; 50 ppm accuracy

– Key Features

• USB 2.0 Hi-Speed/Full-Speed connectivity
• 4,095-entry scan list memory for flexible channel sequencing
• Overvoltage protection on all analog inputs
• NI-DAQmx driver included for configuration and measurement

– Typical Applications

• Laboratory automation and benchtop instrumentation
• Design verification and prototype testing
• Manufacturing test and quality control
• Research data acquisition

– Compatibility & Integration

NI-DAQmx software framework provides standardized driver support and simplified multi-device integration.

MPN

USB-6229

Frequency Range

80 MHz base clock (counters); 10 MHz and 100 kHz base clocks (frequency generator)

Voltage / Current Range

±0.2 V to ±10 V (analog input); ±10 V (analog output); ±5 mA output current drive

Brand Name

National Instruments

Reviews

There are no reviews yet.

Be the first to review “National Instruments USB-6229”

Your email address will not be published. Required fields are marked *

Product Condition & Availability
National Instruments USB-6229 is in excellent working condition and has been thoroughly tested for performance and reliability. We offer both new and professionally refurbished options, depending on availability and customer preference.

 

Integrated Solutions & Deployment Support
Beyond individual products, Aumictech provides end-to-end solutions for manufacturing line deployment and test station setup. Our team can assist with system integration, configuration, and equipment selection tailored to your production requirements.

Trusted Industry Experience
With over a decade of experience, Aumictech is a recognized leader in RF and optical test equipment sales and services. All units are supported by our in-house calibration and repair facility based in Downingtown, PA, ensuring technical reliability and long-term value.

Customer Commitment
We’re committed to exceptional customer service, offering a 15-day return or replacement (ROR) policy for peace of mind. Our team is always available to assist with pre- and post-sale support.

Fast Shipping & Flexible Payments
We offer rapid global shipping through FedEx, UPS, and DHL, with most orders dispatched within 1–3 business days. Multiple secure payment options are available, including PayPal, ACH, wire transfers, and major credit cards.

You May Also Like