The NI PXIe-1071 is a 4-slot, 3U PXI Express chassis engineered for modular test and measurement systems requiring high-bandwidth signal distribution. It delivers up to 3 GB/s maximum system bandwidth through a PXI Express backplane, supporting demanding applications in automated test, data acquisition, and instrumentation. The chassis accommodates both PXI Express modules and standard PXI hybrid-compatible modules across three peripheral slots plus one system slot with three expansion slots, enabling flexible configurations for diverse measurement requirements.
– Technical Specifications
Chassis Configuration
• 4-slot, 3U form factor with 1 system slot and 3 peripheral slots
• Accepts 3U PXI Express, standard PXI hybrid, CompactPCI (PICMG 2.0 R 3.0), and CompactPCI Express modules
• Each hybrid slot: x4 PCI Express link and 32-bit, 33 MHz PCI connection to system slot
• Maximum system bandwidth: 3 GB/s
Power Distribution
• AC Input: 100 to 240 VAC nominal, 90 to 264 VAC operating range, 47 to 63 Hz
• Maximum total usable power: 230 W
• Maximum combined output (+3.3 V and +5 V): 125 W, derating to 100 W from 45 °C to 50 °C ambient
• System slot dissipation: 140 W maximum; peripheral slot: 38.25 W maximum
• System slot current: 45 A maximum; -12 V regulation: ±5% at 8 A or less
• Efficiency: 70% typical
Backplane Clocks
• 10 MHz reference (PXI_CLK10): 500 ps max slot-to-slot skew, ±25 ppm accuracy, 5 ps RMS jitter (10 Hz–1 MHz), 45–55% duty cycle
• 100 MHz reference (PXIe_CLK100/PXIe_SYNC100): 100 ps max skew, ±25 ppm accuracy, 3 ps RMS jitter (10 Hz–12 kHz) and 2 ps RMS (12 kHz–20 MHz)
Environmental
• Operating: 0 °C to 50 °C (IEC-60068-2-1/2-2, MIL-PRF-28800F Class 3 low / Class 2 high)
• Storage: –40 °C to 71 °C
– Key Features
• High-bandwidth PXI Express backplane with 3 GB/s throughput
• Hybrid slot architecture supporting legacy PCI and modern PCI Express modules
• Dedicated system and peripheral slot power allocation
• Low-jitter, precision timing references for synchronization-critical applications
• Wide input voltage tolerance for global deployment
– Typical Applications
• Automated test equipment (ATE) systems
• Data acquisition and signal processing
• RF and microwave measurement systems
• Industrial process monitoring and control
– Compatibility & Integration
The PXIe-1071 integrates PXI Express modules, standard PXI hybrid modules, and CompactPCI variants within a single chassis. Direct PCI Express and PCI connections from hybrid slots to the system slot enable parallel, low-latency communication paths. Support for 4-slot-wide embedded controllers centralizes system intelligence.























Reviews
There are no reviews yet.