The NI SCC-AI04 is a 2-channel isolated analog input module that delivers high-accuracy voltage measurements in electrically noisy environments. It integrates signal conditioning, filtering, and 300 V working isolation to extract low-amplitude signals from high-common-mode voltages. The module amplifies input signals with a gain of 2 and applies a 3-pole lowpass filter at 10 kHz bandwidth to improve measurement resolution and accuracy.
– Technical Specifications
• Channels: 2 (NRSE — Non-Referenced Single-Ended)
• Input Range: ±5 V
• Output Range: ±10 V
• Gain: 2
• Bandwidth: 10 kHz
• Filter: 3-pole lowpass
• Isolation: 300 V working isolation; module-to-module isolation provided (not between channels)
• Gain Accuracy: 50 PPM/°C; Maximum gain error 4.5%
• Analog Power: Up to 410 mW
• Digital Power: 650 mW maximum
• Operating Temperature: 0 to 50 °C
• Storage Temperature: –20 to 70 °C
• Humidity: 10 to 90% RH (non-condensing)
• Connectors: 1 × 20-pin right-angle male, 1 × 4-pin screw terminal
• Weight: 1.0 oz
– Key Features
• Bank isolation minimizes cross-channel interference while maintaining common-mode rejection
• Integrated signal conditioning and filtering reduce external component count
• Cascadable architecture supports expansion of input channels
• Switching capability integration available with relay modules
– Typical Applications
• Noise-sensitive analog measurements in industrial and lab environments
• Low-level signal acquisition from high common-mode voltage sources
• Multi-channel data logging with DC to 10 kHz signal bandwidth
– Compatibility & Integration
The SCC-AI04 mounts on NI SCC carrier boards (SC-2345, SC-2350, SCC-68) and interfaces with National Instruments E/M Series DAQ devices. Programming and configuration use NI-DAQmx driver software, LabVIEW, LabWindows/CVI, and Measurement & Automation Explorer (MAX).