NI SCXI-1129 High-Density Multiconfiguration Matrix

SKU: SCXI-1129Categories: Signal Conditioning Modules
Brand: NI
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • 100% Verified & Tested Equipment
  • Rental Units Available

The NI SCXI-1129 is a high-density, multiconfiguration matrix switching module designed for the SCXI platform. It provides a versatile solution for automated testing and signal routing applications, offering a variety of switching topologies and high channel density within a single SCXI module. Ideal for applications requiring flexible signal management and automated test configurations.

Request Repair
Product Starting From:

$0.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote SCXI-1129
Equipment info

The NI SCXI-1129 is a high-density multiconfiguration matrix switching module for the SCXI platform, delivering 256 crosspoints in a single slot. This electromechanical relay matrix supports multiple topology configurations—from 4 × 64 down to four independent 4 × 16 matrices—enabling flexible signal routing for automated test systems. Gold/gold-clad silver contacts handle up to 1 A per channel with 30 W switching power and 2 A carry current. Initial DC path resistance remains below 1 Ω, with thermal EMF under 9 μV for precision measurements.

– Technical Specifications

Switching Matrix
• 256 crosspoints, high-density configuration
• Topologies: 4 × 64, 2 × 32, 2 × 8 × 16, 4 × 4 × 16, or single 16 × 16 (2-wire)
• Maximum switching power: 30 W per channel (37.5 VA)
• Maximum switching current: 1 A per channel
• Maximum carry current: 2 A per channel
• Module current limit: 5 A
• DC path resistance: < 1 Ω initial, ≥ 2 Ω end of life
• Thermal EMF: < 9 μV
• Impulse voltage withstand: 800 V
• Signal voltage rating: ≤ 150 V

Dynamic Performance
• Relay operate/release time: 4 ms maximum at 20 °C
• Maximum scan rate: 100 crosspoints/s
• Relay life: 5 × 10⁷ mechanical cycles, 1 × 10⁵ electrical cycles at maximum load
• Channel-to-channel isolation (50 Ω): 80 dB @ 10 kHz, 65 dB @ 100 kHz, 50 dB @ 1 MHz

Triggering
• Input sources: SCXI trigger lines 0–7, rear connector, front panel (minimum pulse width 150 ns)
• Output destinations: SCXI trigger lines 0–7, front panel (1 µs pulse width)

Power & Environment
• Power requirements: 6.3 W @ ±18.5 V, 200 mW @ 5 V
• Operating temperature: 0 °C to 55 °C
• Operating humidity: 10% to 90% noncondensing
• Operating vibration: 5 Hz to 500 Hz, 0.3 grms
• Dimensions: 7.8 × 1.2 × 6.8 in. (19.8 × 3.0 × 17.3 cm)
• Weight: 1 lb (725 g)

– Key Features

• Multiconfiguration topology for test scalability
• Expandable via matrix expansion plugs or high-voltage analog bus adapter
• Latching and nonlatching relay options
• Fast switching: 4 ms operate/release time
• Low contact resistance and thermal EMF for precision analog work
• Compact single-slot SCXI form factor

– Typical Applications

Automated test systems requiring high-channel-count signal routing, low-voltage precision measurements, RF/analog signal switching, and flexible matrix configurations within constrained physical space.

– Compatibility & Integration

Integrates directly into SCXI platforms. Trigger I/O via SCXI lines 0–7 or front/rear connectors. Matrix expansion supported through dedicated plugs, cables, and high-voltage analog bus adapters.

MPN

SCXI-1129

Frequency Range

10 kHz to 1 MHz

Voltage / Current Range

1 A per channel maximum, 2 A carry current, Signal voltage ≤ 150 V

Brand Name

NI

Reviews

There are no reviews yet.

Be the first to review “NI SCXI-1129 High-Density Multiconfiguration Matrix”

Your email address will not be published. Required fields are marked *

Product Condition & Availability
NI SCXI-1129 High-Density Multiconfiguration Matrix is in excellent working condition and has been thoroughly tested for performance and reliability. We offer both new and professionally refurbished options, depending on availability and customer preference.

 

Integrated Solutions & Deployment Support
Beyond individual products, Aumictech provides end-to-end solutions for manufacturing line deployment and test station setup. Our team can assist with system integration, configuration, and equipment selection tailored to your production requirements.

Trusted Industry Experience
With over a decade of experience, Aumictech is a recognized leader in RF and optical test equipment sales and services. All units are supported by our in-house calibration and repair facility based in Downingtown, PA, ensuring technical reliability and long-term value.

Customer Commitment
We’re committed to exceptional customer service, offering a 15-day return or replacement (ROR) policy for peace of mind. Our team is always available to assist with pre- and post-sale support.

Fast Shipping & Flexible Payments
We offer rapid global shipping through FedEx, UPS, and DHL, with most orders dispatched within 1–3 business days. Multiple secure payment options are available, including PayPal, ACH, wire transfers, and major credit cards.

You May Also Like

Can't Find The Right Product? Contact Us.