NI USB-6343 Multifunction I/O Device

SKU: USB-6343Categories: Data Acquisition Systems (DAQ)
Brand: NI
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • 100% Verified & Tested Equipment
  • Rental Units Available

The NI USB-6343 is a high-performance multifunction I/O device for USB, offering analog input, analog output, digital I/O, and counter/timer functionality. It is ideal for a variety of applications, including data logging, automated testing, and control systems.

Request Repair
Product Starting From:

$0.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote USB-6343
Equipment info

The NI USB-6343 is a high-performance multifunction I/O device delivering integrated analog input, analog output, digital I/O, and counter/timer capabilities through USB connectivity. Built on National Instruments’ X Series architecture and NI-STC3 timing technology, it provides the synchronization precision and channel density required for data acquisition, automated testing, and control applications. The device supports 32 single-ended or 16 differential analog inputs at 16-bit resolution with 500 kS/s sampling, four 16-bit analog outputs, 48 bidirectional digital I/O channels, and four 32-bit counter/timer channels.

– Technical Specifications

Analog Input
• 32 single-ended or 16 differential channels
• 16-bit ADC resolution
• Maximum sample rate: 500 kS/s
• Input impedance (device on): >10 GΩ parallel with 100 pF
• Input impedance (device off): 1,200 Ω
• Input bias current: ±100 pA
• Small signal bandwidth (−3 dB): 1.2 MHz
• Input FIFO buffer: 2,047 samples
• Scan list memory: 4,095 entries
• Overvoltage protection (device on): ±25 V for up to two AI pins
• Overvoltage protection (device off): ±15 V for up to two AI pins
• Input current during overvoltage: ±20 mA maximum per AI pin
• Absolute accuracy (full scale): 2,190 μV with 3 σ coverage factor

Analog Output
• 4 channels, 16-bit DAC resolution
• Maximum update rates: 900 kS/s (1 ch), 840 kS/s (2 ch), 775 kS/s (3 ch), 719 kS/s (4 ch)
• DNL: ±1 LSB
• 16-bit monotonicity guaranteed
• DC output coupling

Digital I/O
• 48 bidirectional channels
• Hardware-timed digital I/O: up to 1 MHz for 32 channels

Counter/Timers
• 4 channels, 32-bit resolution
• Functionality: PWM, encoder, frequency, event counting

Timing & Synchronization
• NI-STC3 timing and synchronization technology
• Independent analog and digital timing engines

– Key Features

• Large channel count supports multi-signal monitoring and control
• >10 GΩ input impedance minimizes loading effects on sensitive sources
• 1.2 MHz small signal bandwidth extends AC measurement capability
• ±25 V transient protection preserves device integrity during overvoltage events
• 2,047-sample input FIFO reduces CPU overhead in streaming applications
• 4,095-entry scan list enables complex acquisition sequences without firmware intervention

– Typical Applications

• Precision data logging and monitoring
• Automated test and measurement systems
• Real-time process control
• Sensor interfacing and signal conditioning
• PWM-based motor and power electronics control

– Compatibility & Integration

USB connectivity enables straightforward integration with standard computers and test benches. NI-STC3 architecture provides timing alignment across analog and digital domains for synchronized multi-channel operations.

MPN

USB-6343

Voltage / Current Range

±15 V (overvoltage protection, ±20 mA (maximum input current during overvoltage per AI pin), ±25 V (overvoltage protection, device off), device on)

Brand Name

NI

Reviews

There are no reviews yet.

Be the first to review “NI USB-6343 Multifunction I/O Device”

Your email address will not be published. Required fields are marked *

Product Condition & Availability
NI USB-6343 Multifunction I/O Device is in excellent working condition and has been thoroughly tested for performance and reliability. We offer both new and professionally refurbished options, depending on availability and customer preference.

 

Integrated Solutions & Deployment Support
Beyond individual products, Aumictech provides end-to-end solutions for manufacturing line deployment and test station setup. Our team can assist with system integration, configuration, and equipment selection tailored to your production requirements.

Trusted Industry Experience
With over a decade of experience, Aumictech is a recognized leader in RF and optical test equipment sales and services. All units are supported by our in-house calibration and repair facility based in Downingtown, PA, ensuring technical reliability and long-term value.

Customer Commitment
We’re committed to exceptional customer service, offering a 15-day return or replacement (ROR) policy for peace of mind. Our team is always available to assist with pre- and post-sale support.

Fast Shipping & Flexible Payments
We offer rapid global shipping through FedEx, UPS, and DHL, with most orders dispatched within 1–3 business days. Multiple secure payment options are available, including PayPal, ACH, wire transfers, and major credit cards.

You May Also Like

Can't Find The Right Product? Contact Us.