The Rigol DSG830 is an RF signal generator operating from 9 kHz to 3.0 GHz, delivering output power from -110 dBm to +13 dBm into 50 Ω. Built for research, development, and production testing, it combines frequency stability of ±1 ppm with phase noise below -110 dBc/Hz at 1 GHz (20 kHz offset) and harmonic distortion under -35 dBc. The instrument supports analog modulation (AM, FM, PM) with internal or external sources, plus configurable digital modulation options. Frequency resolution reaches 1 Hz; output level resolution is 0.1 dB. Sweep capabilities include frequency, amplitude, and phase modes with dwell times from 10 ms to 200 s, enabling flexible test automation. RF output connects via Type N connector (50 Ω). Remote control and instrument integration occur through USB and Ethernet interfaces. Reverse power protection tolerates up to +20 dBm input. The DSG830 operates on 100-240 VAC, 50/60 Hz across a 5°C to 40°C temperature range, making it suitable for bench-top and integrated test systems.
– Technical Specifications
Frequency & Stability
• Frequency range: 9 kHz to 3.0 GHz
• Resolution: 1 Hz
• Accuracy: ±1 ppm (after 1 hour warm-up)
• Aging rate: < 0.1 ppm/year
Output Power
• Range: -110 dBm to +13 dBm (50 Ω)
• Level resolution: 0.1 dB
• Accuracy (1 GHz, levels ≥ -50 dBm): ±0.5 dB
• Flatness (1 GHz, levels ≥ -50 dBm): ±0.3 dB
• Reverse power protection: +20 dBm maximum input, 50 VDC
Signal Purity
• Phase noise (1 GHz, 20 kHz offset): < -110 dBc/Hz
• Harmonic distortion (1 GHz, +10 dBm): < -35 dBc
• Non-harmonic spurious (1 GHz, +10 dBm): < -40 dBc
Modulation
• AM depth: 0% to 100%
• FM deviation: 0 Hz to 200 kHz
• PM deviation: 0° to 360°
• AM distortion (1 kHz): < 1%
• FM distortion (1 kHz, 5 kHz deviation): < 0.5%
• Source: Internal or external
Sweep
• Types: Frequency, amplitude, phase
• Modes: List, single, step
• Dwell time: 10 ms to 200 s
– Key Features
• 1 Hz frequency resolution for precision tuning
• Type N RF output connector (50 Ω)
• BNC external modulation and trigger connectors
• USB and Ethernet control interfaces
• Configurable digital modulation options
– Typical Applications
• Component and subsystem characterization
• Filter and amplifier testing
• Receiver sensitivity and blocking measurements
• Phase-locked loop validation
• Production alignment and calibration
– Compatibility & Integration
USB and Ethernet connectivity enable integration into automated test systems. External modulation accepts signals via BNC connector. Trigger I/O supports synchronization with other instruments. Power supply: 100-240 VAC, 50/60 Hz. Operating environment: 5°C to 40°C.

















Reviews