The Spellman SL60 is a compact high voltage power supply engineered for precision B2B applications requiring stable, regulated DC output. It delivers 0 to 60 kV across multiple current-rated models, with proprietary inverter control technology that maintains fault-free operation in transient and arcing environments. Efficiency exceeds 85%, and integrated arc protection—including Arc Quench, Arc Count, and Arc Trip—ensures safe, reliable performance. The unit accepts 115 Vac or 220 Vac input (±10%, 50/60 Hz) and integrates into larger systems rather than operating standalone.
– Technical Specifications
Electrical Performance
• Output Voltage: 0 to 60 kV DC
• Output Current: Varies by model suffix (SL60×10, SL60×30, SL60×60 designations)
• Input: 115 Vac or 220 Vac ±10%, 50/60 Hz (specify at order)
• Line Regulation (Voltage): ±0.005% of full voltage +500 mV
• Line Regulation (Current): ±0.005% of maximum current (±10% input change)
• Load Regulation (Voltage): 0.005% of maximum voltage +500 mV
• Load Regulation (Current): 0.01% of maximum current ±100 µA
• Ripple: 0.1% p-p +1 Vrms of maximum output
• Temperature Coefficient: 100 ppm/°C (higher stability available on special order)
• Stability: 100 ppm/hour after 30-minute warm-up
• Efficiency: Greater than 85%
• Polarity: Positive, negative, or reversible output (reversible standard to 8 kV)
– Key Features
• Ten-turn potentiometer voltage and current adjustment with lockable counting dials
• Programmable voltage and current (remote programming via voltage source or external resistance)
• 3½-digit digital meters for voltage and current monitoring (±1 least significant digit)
• ON/OFF circuit breaker with lamp indicator
• High voltage ON/OFF switches with status indicators
• Arc protection features: Arc Quench, Arc Count, Arc Trip
• Status indicators for control mode, interlock, HV inhibit, overcurrent, overvoltage, arc detection, regulation error, and overtemperature
– Typical Applications
High voltage testing, precision electrostatic applications, X-ray generation, and industrial processes requiring stable, regulated DC output in the 0–60 kV range.
– Compatibility & Integration
Designed for OEM system integration with modular architecture supporting multiple input voltages and output current ratings via model designation.