The Tektronix P6015A is a 1000:1 passive high-voltage probe that extends oscilloscope measurement capability to hazardous voltage levels. Engineered for DC voltages to 20 kV and transient peaks to 40 kV, it delivers the bandwidth and input impedance required for power electronics characterization while maintaining signal fidelity across fast edges. The probe uses a permanently sealed silicone dielectric, eliminating maintenance and ensuring consistent performance in field conditions.
– Technical Specifications
• Attenuation: 1000:1
• Bandwidth: DC to 75 MHz
• Risetime: 4 ns
• Input Impedance: 100 MΩ
• Input Capacitance: 3.0 pF
• Compensation Range: 7 pF to 49 pF
• Cable Length: 3 meters
• Maximum Input Voltage: 20 kV DC; 40 kV peak (100 ms duration). Derating applies above 460 kHz, for duty cycles exceeding 10%, pulse durations longer than 100 ms, altitudes above 8000 feet (2440 m), and humidity above 80% at 25°C, 70% at 35°C, or 30% at 50°C.
– Key Features
• Compact compensation box fits adjacent amplifier inputs
• BNC output connector
• Interchangeable probe tips: hook, banana plug, and crocodile clip
• High-impact thermoplastic housing
• UL3111-1, EN61010-1, IEC61010-2-031, CSA1010.1, and CSA1010.2.031 compliant
• Optional automatic readout scaling (1000:1) on compatible Tektronix digital oscilloscopes
– Typical Applications
• Power supply design and characterization
• Motor drive control circuits
• Electronic ballast testing
• Power semiconductor validation
• Switch-mode power supply control
• UPS system measurement
• Power converter analysis
• Ground-referenced high-voltage testing
– Compatibility & Integration
The P6015A works with oscilloscopes featuring 1 MΩ input resistance and 7 pF to 49 pF input capacitance. Automatic readout display is available on most Tektronix digital oscilloscopes, including 5 Series MSO and 2 Series MSO platforms. Ground lead and carrying case included.