The Wavetek 2001 is a versatile sweep/signal generator spanning 1 to 1400 MHz across three overlapping bands. It delivers continuous-wave, swept, and delta-frequency operation across laboratory, service, and production environments. The instrument combines broad frequency coverage with flexible modulation, remote control capability, and modular marker provisions—all within a compact 50 Ω output stage designed for reliable, repeatable measurements.
– Technical Specifications
Frequency Range
• 1–500 MHz, 450–950 MHz, 900–1400 MHz (three overlapping bands)
• Tuning sensitivity: 16 MHz/volt (approximate)
• Residual FM: Less than 15 kHz
• Frequency drift: 100 kHz per 5 minutes; 2 MHz per 8 hours after warm-up
Output Level
• +10 dBm to −80 dBm (or +9 dBm to −81 dBm)
• 70 dB range in 10 dB steps with 20 dB vernier control
• Output impedance: 50 Ω; VSWR ≤1.3:1
• Output accuracy: ±0.5 dB to 500 MHz; ±1 dB to 1 GHz; ±2 dB to 1.4 GHz
• Spurious signals: At least 26 dB below output (10–1400 MHz)
Operating Modes
• Continuous Wave (CW)
• Start/Stop sweep
• Delta-frequency (Δf) sweep
• Manual, triggered, repetitive, line-lock, end-to-end, and up/down sweep modes
• Sweep rate: Less than 10 ms to over 100 seconds (adjustable)
• Sweep width: 50 kHz to 500 MHz or 200 kHz to 1000 MHz (externally controllable via voltage)
• Retrace blanking: Selectable on/off
Modulation
• Optional 1 kHz square-wave AM: Up to 100% modulation
• FM deviation: ±250 MHz at rates to 4 kHz; reduced deviation and linearity to 100 kHz
• External AM/FM control via rear REMOTE jack
Markers
• Six plug-in marker slots (single-frequency or harmonic modules)
• Standard harmonic markers: 1, 10, 50 MHz
• Optional markers: 0.2, 1, 5, 20 MHz harmonics
• 90° tilt provision and X-Y plotter rectification
• External marker input supported
Display & Control
• LED frequency display
• Remote frequency, sweep width, and output attenuation programming
• External leveling (ALC) input: 0.2–2 V negative signal
• SCOPE VERT. OUTPUT: BNC connector for demodulated swept signal
Power
• 115/230 VAC ±10%, 50–60 Hz, approximately 20 W
– Key Features
• Three overlapping frequency bands eliminate retuning during band transitions
• Six-decade output range with fine vernier enables precise level setting
• Multiple sweep modes and external voltage control suit automated test systems
• Modular marker architecture accommodates customer-specific measurement frequencies
• Optional AM and full FM capability to ±250 MHz supports complex signal simulation
– Typical Applications
• RF component characterization and filter response testing
• Communications system alignment and troubleshooting
• Production testing and final system calibration
– Compatibility & Integration
• 50 Ω output standard; matched interface for network and spectrum analyzers
• Rear REMOTE jack enables integration with automated test equipment and external modulators
• External ALC supports leveling feedback from power meters or network analyzers


















Reviews