Test Equipment Repair Services – RF & Optical Specialists | Aumictech
Precision Engineering • Component-Level Diagnostics • OEM-Standard Restoration
Aumictech provides engineered repair solutions for RF, optical, and fiber-optic test equipment used in research laboratories, semiconductor facilities, telecom networks, photonics manufacturing, and advanced measurement environments.
Our repair processes are built around technical accuracy, traceability, and long-term stability, ensuring every instrument returned to the customer meets or exceeds original performance specifications.

Comprehensive Repair Coverage
Aumictech’s repair services support:
Optical test and measurement instruments
Optical spectrum analyzers
Tunable lasers and light sources
Optical power meters and lightwave meters
RF and microwave analyzers and generators
Vector network analyzers
Fusion splicers (standard and polarization-maintaining)
OTDRs and fiber inspection platforms
Power sensors and frequency counters
- And many more…
Repair capabilities include electronic, optical, mechanical, and firmware-level restoration. Each instrument receives a complete evaluation to determine the corrective actions required.
Support for Legacy and Discontinued Equipment
Many laboratories continue to rely on instruments that are no longer supported by the manufacturer.
Aumictech maintains repair capability for a wide range of legacy optical, RF, and fusion splicing systems, allowing customers to extend equipment service life and avoid premature capital replacement.
This includes older optical spectrum analyzers, early model fusion splicers, discontinued RF analyzers, and other instruments commonly classified as “obsolete” by OEMs.
Quality & Technical Standards
Aumictech’s repair services follow structured engineering controls, including:
Defined diagnostic and test procedures
Calibrated reference standards
ESD-controlled handling processes
Documentation of all findings and corrective actions
Post-repair performance confirmation and calibration
Each completed repair is supported by detailed reporting and traceability.
Service Advantages
Customers rely on Aumictech for:
Support across multiple instrument categories
Capability for both modern and legacy equipment
Cost-effective repair options
Predictable turnaround times
Detailed reporting and transparency
Calibration included with completed repairs
Domestic and international service availability
What Makes Aumictech Different?
Technical Expertise: Our engineers are experienced in repairing and refurbishing a wide range of RF, microwave, and optical test instruments.
In-House Repairs: All services are completed in our Downingtown, PA repair lab. No outsourcing.
Fast Turnaround: Most repairs completed within 1–3 business days.
Return Guarantee: All repairs include our standard 15-day Return on Repair (RoR) policy.
Global Service: We offer worldwide repair services with insured shipping through FedEx, UPS, and DHL.
Why Optimize Repairs Instead of Replacing?
Cost savings of up to 70% compared to OEM replacements
Faster turnaround than OEM service centers
Helps extend the life of legacy equipment no longer supported by manufacturers
Avoid downtime and keep your lab or production running smoothly
Shipping & Payment Options
We offer domestic and international repairs
Use your carrier account or ours (UPS, FedEx, DHL)
We accept PayPal, credit/debit cards, ACH, and wire transfers
Optical Spectrum Analyzer (OSA) Repairs
We service Ando, Yokogawa, Keysight/Agilent, Anritsu, Bristol, and EXFO OSAs.
Common OSA Failures We Fix
Wavelength drift
No sweep or slow sweep
Grating motor stall or vibration
HDD failure / firmware boot loops (common on Ando AQ6317 series)
Dim or dead LCD displays
Detector aging (weak sensitivity, poor power accuracy)
Broken input connector assemblies
Calibration error messages
Our Repair Process Includes
Restoring or replacing hard drives (SSD conversions for older models)
Rebuilding sweep/grating motors
Optical bench cleaning and internal alignment
Detector/power amplifier repair
Restoring corrupted firmware
Replacing LCD/backlight assemblies
Full wavelength and power verification after repair
Aumictech is one of the few labs capable of restoring older Ando analyzers that OEMs consider obsolete.
Fujikura & PM Fiber Fusion Splicer Repairs
We specialize extensively in repairing Fujikura 20PM, 40PM, 45PM, 100P, 100M and standard SM splicers.
Common Issues We Repair
High splice loss
PM rotational alignment drift
Arc calibration errors
X/Y/Z motor faults
Heater tray failure
Touchscreen not responding
Dust contamination causing misalignment
Electrode burn or arc instability
Our Splicer Repair Capabilities
PM axis optical realignment
Motor rebuild and recalibration
Replacement of electrodes, heater, fans, sensors
Touchscreen and LCD repair
Cleaning and micro-polishing of V-grooves
Recalibrating arc profiles and loss estimation
Every splicer undergoes a full alignment and test splice certification before return.
RF & Microwave Equipment Repairs
We restore a wide range of RF and microwave gear used in production lines, military labs, and R&D facilities.
Equipment We Repair
Spectrum analyzers
Signal generators
VNAs
Power sensors and meters
Frequency counters
Modulation analyzers
Typical Failures
No RF output
Broken input connectors
Wrong amplitude readings
Failing attenuators
Power supply instability
YIG oscillator or PLL unlock
Display/LCD failure
Firmware corruption
Our Repair Work Includes
Front-end RF path repair
Replacing attenuators, mixers, IF amplifiers
Oscillator and synthesizer troubleshooting
LCD and touchscreen replacement
Reflowing or replacing failing components
Full RF performance verification
Every RF repair concludes with traceable power and frequency accuracy checks.
OTDR, Tunable Laser & Lightwave Meter Repairs
We Repair
OTDRs (EXFO, Viavi, Anritsu)
Tunable laser sources
Optical power meters
Lightwave multimeters
Common Symptoms
No trace output
Incorrect distance measurements
Dead detector or SLED module
Range switching failure
Frozen UI or non-booting units
Wavelength instability or drift
What We Do
Rebuild laser/detector stages
Firmware reload and OS repair
Optical alignment and cleaning
Restoring burnt connectors or ports
Replacing internal boards and power supplies
Onsite Repair on demand
We use Latest tools and Equipment for your repairs
Thorough Testing before shipping out your Equipment
Get your Quote today. Or contact us at Sales@aumictech.com
Call +1 (484) 841-9341
| Equipment Category | Supported Brands | Popular Models | Common Failures / Symptoms | Repair Services Provided |
|---|---|---|---|---|
| Optical Spectrum Analyzers (OSA) | Ando, Yokogawa, Keysight/Agilent, Anritsu, Bristol, EXFO, HP, Photonetics Walics | AQ6317B, AQ6317C, AQ6319, AQ6331, AQ6370D/C/B, AQ6380, AQ6370E, 86140B, MS9740A, 70950B, 3651HR12, 86146A/B, 86145A/B, 86140A/B | • Wavelength drift • Dead/weak detector • HDD failure / boot loop • Dim or dead LCD display • Slow sweep / motor stall • Calibration error messages • No trace or unstable readings | • HDD/SSD replacement & OS restore • Grating motor rebuild • Optical bench realignment • LCD/touchscreen replacement • Power supply repair • Detector/power amplifier repair • Firmware restoration & corruption repair |
| Tunable Lasers & Light Sources | Keysight, Santec, Yenista, Ando, Anritsu | 81680A, 81608A, TLS-55, Tunable ECL Lasers | • Unstable wavelength • Low output power • Excessive ASE noise • No output / laser shutdown • Overheating or fan faults | • Laser module repair • Output power amplifier restoration • Temperature control repair • Optical alignment • Fan/rear board replacement |
| Optical Power Meters & Lightwave Meters | Keysight, EXFO, Viavi/JDSU, Yokogawa, Anritsu | 8163B, 81634B, AQ2170, IQ-1600, JW3208 | • Incorrect power readings • Zero offset problems • Dead detector head • Range not switching • Display issues | • Detector replacement • Power amplifier repair • Range switching repair • LCD/touchscreen replacement • Firmware reset & recalibration |
| OTDRs & Fiber Inspection Tools | EXFO, Viavi, Anritsu, Yokogawa | FTB-1, FTB-200, MTS-6000, MW9076 | • No trace / weak backscatter • Distance error • Dead laser/detector • Frozen UI / boot failure • Broken connectors | • Laser/detector repair • PCB repair • Touchscreen replacement • Connector port rebuild • Firmware reload & diagnostics |
| Fusion Splicers (SM & PM) | Fujikura, Sumitomo, Fitel, INNO | FSM-20PM, FSM-40PM, FSM-45PM, FSM-100P, FSM-100M | • High splice loss • PM axis drift • Arc failure • Z/X/Y motor error • Heater failure • Bad electrodes • Touchscreen not responding | • PM axis realignment • Motor rebuild & recalibration • Arc circuit repair • Electrode replacement • Heater unit repair • Touchscreen/LCD replacement • Full internal cleaning & restoration |
| Spectrum Analyzers | Keysight/Agilent, Rohde & Schwarz, Tektronix, Anritsu | 856x Series, E440x, N9000, FSV, FSU, MS266x | • No RF input • Wrong amplitude • Failing attenuator • Broken input connector • Cracked LCD • PLL unlock / phase noise issues | • Front-end RF path repair • Attenuator & preamp rebuild • Reference oscillator repair • LCD replacement • Fan/PSU repair • Input connector replacement |
| Signal Generators | Agilent/Keysight, Rohde & Schwarz, Anritsu, Tektronix | E4438C, E8257D, SMU200A, SML Series | • No RF output • Level error • Modulation failure • Frequency drift • Internal error messages | • RF output module repair • Power amp repair • Modulation board replacement • OCXO/TCXO repair • Firmware recovery |
| Vector Network Analyzers (VNAs) | Keysight, Rohde & Schwarz, Anritsu | 8753D, E5080A, PNA Series, ZVL, ZNB Series | • Wrong S-parameters • Source port failure • Port damage • Display failure • Boot loop / no startup | • Port module repair • Source/receiver chain rebuild • Touchscreen replacement • Power supply repair • Firmware reload & diagnostics |
| RF Power Meters & Sensors | Keysight, Boonton, Anritsu, Rohde & Schwarz | E4412A, 848x sensors, 501 Series | • Incorrect readings • Sensor burned/open • Cable/connectivity issues • No power-up | • Sensor head repair • Internal amp module replacement • Range switching repair • Cable/connector repair |
Why Companies Trust Aumictech for Repairs
Factory-Level Precision
Every repair is performed with the same discipline and methodology used by major OEMs. We use calibrated references, optical standards, RF generators, power sensors, and wavelength anchors to verify every step of the repair.
Expertise With Legacy & Discontinued Equipment
Our team regularly restores instruments that most OEMs no longer support, including Ando OSAs, early Yokogawa AQ models, Fujikura PM splicers (20PM/40PM/100P), and older Keysight/Agilent analyzers.
Real Engineering Diagnostics
We do not depend on automated scripts. Repairs include detailed diagnostics of:
Power supply rails
Detector front-ends
Laser modules
Sweep motor systems
Arc circuits
Alignment stages
Clock and RF synthesizer chains
HDD and embedded OS failures
Fast Turnaround & Clear Communication
Before work begins, you’ll receive:
A complete evaluation report
Photos or videos (if needed)
A clear repair estimate
Expected turnaround time
Upon completion, every repaired instrument is calibrated and tested before shipment.
