Service & Repair of Ando AQ6315A Optical Spectrum Analyzer OSA
Ando AQ6315A & AQ6315B Optical Spectrum Analyzer – Expert Service, Repair & Precision Calibration
We specialize in the repair, maintenance, and calibration of the Ando AQ6315A and AQ6315B Optical Spectrum Analyzers (OSA) — highly regarded instruments used for broadband and high-resolution optical signal analysis. Trusted across telecom, photonics, and R&D industries, these OSAs provide excellent dynamic range, resolution, and spectral accuracy. Whether your unit is showing signs of drift, signal loss, or internal failure, our team of trained technicians can restore full functionality through in-depth diagnostics, optical alignment, and NIST-traceable calibration.
Complete Repair & Calibration Workflow
Initial Evaluation & Functional Testing
Each AQ6315A/B unit is subjected to a detailed evaluation process to test:
Wavelength accuracy across the 400–1750 nm range
Optical power detection, noise floor, and sensitivity
Sweep operation, resolution bandwidth, and trace stability
Signal detection across wide and narrow span settings
CRT display or LCD functionality, brightness, and controls
Front panel response and communication interfaces (GPIB/RS232)
We simulate live optical signals and test each function to identify hidden issues that may not be visible during routine use.
Common Failures We Repair
No optical signal or inconsistent spectral data
Inaccurate or drifting wavelength measurements
Faulty grating motor or sweep mechanism
Display issues including dead CRT, dimming, or flickering
Boot failures, system errors, or frozen front panels
Input connector damage or internal fiber path contamination
Internal noise floor increase or sensitivity degradation
Component-Level Electronic Repair
Our repair team performs diagnostics and component-level replacement of capacitors, ICs, analog front-end circuits, power supplies, and internal communication modules. We also repair faulty sweep drivers, display circuits, and optical signal amplifiers.
Grating & Optical Path Realignment
Using high-precision tools, we realign the grating and internal monochromator system to correct drift and restore wavelength accuracy. We also clean and recalibrate optical lenses, mirrors, and fiber input ports to reduce internal loss and improve SNR (signal-to-noise ratio).
CRT or Display System Restoration
For units with aging CRT displays, we repair or replace CRT driver boards, restore brightness and contrast levels, and resolve screen flicker or ghosting. We ensure all visual readouts are stable and readable.
Self-Test Validation & Firmware Check
Post-repair, the unit is subjected to internal self-test routines. Where applicable, firmware and EEPROM values are verified or corrected to prevent recurring failures.
NIST-Traceable Final Calibration
Each AQ6315A/B is calibrated using NIST-traceable reference lasers and power sources, including:
Wavelength accuracy verification
Optical power level calibration
Dynamic range and span accuracy testing
Resolution bandwidth calibration
A calibration certificate with before/after test results is included.
Why Trust Us?
Extensive experience with Ando / Yokogawa AQ-series OSAs, including AQ6317B, AQ6370C, and others
Fast turnaround – typically within 2–4 business days
High success rate, even with units in non-booting or low-signal condition
Warranty included with each repair and a 15-day Right of Return
Secure packaging and worldwide shipping support
Accept multiple payment methods: credit cards, PayPal, ACH, and wire transfers
Perfect For:
Optical labs and network equipment vendors needing urgent service
Technicians troubleshooting irregular test data or signal loss
Equipment buyers needing calibration and validation of used OSAs
Businesses extending the life cycle of legacy Ando test instruments
Restore Accuracy and Extend the Life of Your AQ6315A or AQ6315B
If your Ando AQ6315A or AQ6315B Optical Spectrum Analyzer is not performing to expectations — due to optical drift, signal detection issues, or display failure — we’re here to help. Our expert repair and calibration process ensures full restoration to reliable, test-ready condition.
Request a service quote today and let our team professionally restore your Ando spectrum analyzer.
$2,480.00
Service and repair for Ando AQ6315A Optical Spectrum Analyzer (OSA). Professional maintenance to ensure optimal performance and accuracy.
Agilent 856x series Spectrum Analyzer Extender cable
$365.00York / PK Technology FK12 Angled Fiber Cleaver **CALIBRATED**
$2,630.00Yokogawa WT1600 Digital Power Meter
$3,080.00Yokogawa PZ4000 Power Analyzer
$4,480.00Yokogawa PX8000 Precision Power Scope, 100 MS/s, 20 Hz to 6.4 kHz
$31,480.00Yokogawa DLM5058 Mixed Signal Oscilloscope: 8-Channel, 500 MHz
$4,250.00Yokogawa DLM5054 Mixed Signal Oscilloscope: 4-Channel, 500 MHz
$4,250.00Yokogawa DLM5038 Mixed Signal Oscilloscope: 8-Channel, 350 MHz
$4,250.00Yokogawa DLM5034 Mixed Signal Oscilloscope: 4-Channel, 350 MHz
$4,550.00Yokogawa DL7200 CAN Bus Signal Analyzer W D,BS,C10
$1,279.00
Calibration Services
Accurate measurements are critical in every lab and manufacturing environment. That’s why we offer NIST-traceable calibration. Using precision standards and certified reference equipment, our team performs a full verification of wavelength accuracy, power levels, and response time. After calibration, your instrument not only meets but often exceeds factory specifications. Every service includes a calibration certificate to support ISO and quality compliance audits.
Industry Applications
Our repair and calibration services are trusted by telecommunications providers, research labs, universities, and manufacturing plants worldwide. By maintaining tight tolerances and providing quick turnaround, Aumictech helps minimize downtime and maximize productivity. Many of our clients rely on us for scheduled preventive maintenance, ensuring instruments remain accurate during critical testing or production runs.
Cost Efficiency & On-Site Options
Unlike OEM services that often come with long lead times and high costs, Aumictech provides affordable repairs with flexible turnaround options. For large facilities or urgent needs, we also offer on-site calibration—bringing our certified equipment directly to your lab or production line. This reduces shipping delays, minimizes handling risks, and keeps your operations running smoothly without interruption.
Why Choose Aumictech
Choosing Aumictech means partnering with a dedicated repair and calibration lab focused on optical and RF test equipment. With decades of combined expertise, an extensive inventory of replacement parts, and specialized tooling for high-end instruments, we deliver reliable service at a fraction of the replacement cost. Our commitment to quality, precision, and fast turnaround makes us the trusted partner for organizations looking to extend the life and accuracy of their critical equipment.